6 Electrical Code Myths people Should Stop Believing
186K views · Aug 19, 2024 · Howto & Style
Comments · 536
@BackyardMaine · 2 years ago · pinned
FlexiSpot is having their anniversary sale now and a chance to win free orders! 🌟 Use my code ''24AUGE7PLUS” for extra $50 off on E7 PLUS! Trust me, it's a rare treat!<br>FlexiSpot E7 Plus Standing Desk: <a href="https://bit.ly/3WUcJGW">https://bit.ly/3WUcJGW</a> Garage Rack: <a href="https://bit.ly/3M7YMQV">https://bit.ly/3M7YMQV</a>
7
@criticalthinkerAF · 2 years ago
I'm not a licensed electrician but at my own home, I follow the code book. I was an electronic tech, and know enough to follow the book.
14
@RealMichael_D · 2 years ago
The code may not require anti-ox, but there are still manufacturers that require it, and the code states if anti-ox is required by the manufacture, then it is required by the code.
25
@CognitiveHeatsink · 2 years ago
My favorite thing to do is ask people to show me the specific article in the code that allows or forbids something. It feels like many professionals have never even read the code and only know what they were taught as an apprentice. <br><br>*I was typing this out as the video still played. As I was typing you just said "that's what I was taught as an apprentice" 😂
9
@stringlarson1247 · 2 years ago
I was doing some MC recently in the attic and my old Greenlee cutter was in the basement, but my little M12 bandsaw was at hand. I tried it on the MC and obviously, it cut the MC. Just then I used my good ol Klien reamer/debur to remove any edge (there was almost none), I have a ton of old single screw fasteners (not the new ones you show). The protector goes in nice and smooth. <br>It looks like the collar/clap type connectors for use without the bushing may cause issues as the clamp could squeeze down on the cable and bushing too much. <br>BTW: The little M12 bandsaw is great for EMT, RMC, MC, copper, AL, etc.
2
@inspectr1949 · 1 year ago
Now retired, I spent 55 years in the trade as an IBEW Journeyman Electrician, a Municipal Licensed Master Electrician and as a 3rd party Electrical Fire Underwriter Inspector as the the vast majority of electrical inspections in New York State outside of the City are conducted that way, the State is a non licensed state and that way they don't have to create another bureaucracy but farm it out to "3rd party electrical inspection agencies", the problem is they are not regulated and as you can see from my back ground I was over qualified because including my counter parts and the company owners have little or no electrical back ground its just a business, I'm so glad I'm now away from it all.
8
@DolphinAvatar · 2 days ago
At the end there, not trip at all, are you talking about Federal Pacific? I hope those problems have been solved by now with other types of modern breakers.
1
@theskilledpatient · 2 years ago
Two other factors governing the use of anti-short bushings:<br>1, Some agencies require the use of all supplied components from the manufacturer.(whether actually required or not.)<br>2. Some jurisdictions still have the requirement on the books from decades ago. (Hence, why they're still shipped.) <br>Legacy; code, standards, and requirements exist all over industry!
18
@MrFixItGa · 8 months ago
Does anyone even sell household appliances that use an actual 20 amp plug?<br>I can't remember ever seeing one.
1
@weaselhead6771 · 2 years ago
good stuff. you answered most of the questions I could never find. Thanks!!
1
@HowToHomeDIY · 2 years ago
In depth but also simple to understand. As always, great video John!
2
@PhillyFixed · 2 years ago
Clear and concise. Thank you!
Up next

I Discovered This Hidden Wiring Trick In An Old Forum!
LRN2DIY · 1.2M views

Neutral Wire Complete Guide: The Hidden Danger Most People Ignore
Zenthral Code · 157K views

Epic Low Cost Consumer Unit - To Fix Deadly Consumer Unit🤠
Mike Builds - GHC · 232K views

Electrical Wires Too Short? 3 FAST & SIMPLE Fixes
LRN2DIY · 422K views

Electric Vehicle Charger Installation
Making Good · 233 views

Why Neutrals & Grounds are Connected in a Main Panel
Benjamin Sahlstrom · 1.6M views

The Generator Mistake Everyone Makes!
Backyard Maine · 970K views

How Newton Calculated Pi in Just One Afternoon
STEM in Motion by Gaurav · 820K views

The Hidden Generator Mistake.. (Dangerous)
Backyard Maine · 231K views

Why Put Diodes Together In Both Directions? Explained With Examples!
Mr Carlson's Lab · 947K views

Splices And Terminations That Fail Code In The 2026 NEC
Electrician U · 90K views

9 Electrical Myths (You Should Not Believe)!
Backyard Maine · 177K views

Understanding Basic Home Electrical
TX Tool Crib · 52K views

7 Strange Electrical Tricks (That Actually Work)
Backyard Maine · 195K views

7 Horrible Electrical Habits
Backyard Maine · 222K views

5 Electrical Hacks That Save Hundreds (DIY Friendly)
The DIY Guy · 1.2M views

8 Wire Stripper Features Everyone Should Know
LRN2DIY · 4.3M views

What you NEED to know about Boat Electrical (Part 1)
Clark's Adventure · 123K views

7 FATAL Wiring Mistakes Most DIYers Don't Know They Are Making | Most Are Guilty of 3
How To Home · 11M views

SHOCKING Mistakes DIYers Make Installing Metal Electrical Boxes!
How To Home · 1.6M views

What Pros Know About Screws That Beginners Don't.
Five Duck Studio · 9.8M views

Sub Panels Explained - Why are neutral and ground separated?
The Engineering Mindset · 2.8M views

The Most Dangerous Wire in Your Home
Backyard Maine · 142K views

10 Mistakes DIYers Make in Electrical Panels
Backyard Maine · 764K views

The Hidden Code Rule Almost Everyone Misses.
Backyard Maine · 171K views

Stranded Wire vs Solid Wire: Which One Is Better?
Zenthral Code · 111K views