Splices And Terminations That Fail Code In The 2026 NEC

90K views · Jan 19, 2026 · Education

Comments · 281

  • @russellstyles5381 · 8 months ago

    A surprisingly large part of the code seems to boil down to "don't be stupid".

    91

  • @quietscruffianinthecorner · 8 months ago

    Its great to remind all of us to do the highest quality we can. Unfortunately the tradesmen who realy need to hear these reminders likely dont watch these videos. Keep up the great work on these videos.

    44

  • @storm-aircorporation6540 · 1 month ago

    My go to site for electrical information. Thanks for helping folks understand quality electrical work.

  • @f-dog13tactics61 · 8 months ago

    Some old Electrician is going to crap his pants when he tries to find something in the 2029 code book

    81

  • @keithlilly4007 · 8 months ago

    Love the format of picking a code article and talking about it with real examples!

    6

  • @aaperry1 · 8 months ago (edited)

    People at the supply house will often just refer to everything as THHN even though what they carry is also rated as THWN-2. So I just pulled this up to get a more detailed history: <br><br>&quot;Most of the stranded copper building wire stocked today is manufactured and labeled as THHN/THWN-2, meaning it is insulated for 90°C in dry locations under the THHN designation and 90°C in both wet and dry locations under the THWN-2 designation, which has effectively become the modern standard because the NEC treats most real-world conduit installations - including underground runs, slab-in-grade conduit, exterior raceways, and any location subject to moisture - as wet locations, making single-rated THHN largely a legacy product that is technically still permitted only in dry interior spaces but rarely stocked, while the 90°C insulation rating is primarily used for adjustment and derating calculations since final ampacity is governed by the 60°C or 75°C temperature rating of the terminations.&quot;<br><br>It still doesn&apos;t hurt to double-check on the insulation jacket

    49

  • @alancornwall5589 · 8 months ago

    It drives me nuts when I see people tightening a terminal screw with an impact driver.

    31

  • @SpaceBallerOne · 8 months ago

    I&apos;m not even in the trades myself and a lot of these updates are just good sense to me. <br><br>I see it as if I can look back and be proud of what i put together, then I&apos;m probably &nbsp;on the right path. Code is just the minimum, one can always go above that line.

    8

  • @TomCee53 · 8 months ago

    <a href="https://www.youtube.com/watch?v=PJWSare36bY&amp;t=761">12:41</a> Thank you for positive thought on Wago, etc. Too many people bad mouth them with no justification other than feelings.

    24

  • @nts9211 · 4 months ago

    Wagos are so awesome. I use them all the time in my job as an automation electrician.

    1

  • @randallthomas5207 · 8 months ago

    The codes are changing so things line up with the other codes and the standards for writing contract specifications, written to conform with the Construction Specifications Institute, Master Format. &nbsp;As a Guy who writes technical specs, I understand what is going on. &nbsp;But I’m not sure I agree with it.

    9

  • @lpduncan · 8 months ago

    You are a great electrician. &nbsp;I like the test points notice not saying I&apos;m in love with the waffle that you cannot take out or any termination that will shorten the wire in for future work. I have seen the work done by jack legs it sucks

    2

Up next

LIVE

This Connector Might Change the Way You Work (If You Let It)

Electrician U · 221K views

LIVE

Everything You Need to Know About Electrical Panels

Electrician U · 157K views

LIVE

Where and Why Do We Need GFCI Protection?

Electrician U · 161K views

LIVE

MC Cable vs AC Cable: Are They the Same Thing?

Electrician U · 68K views

LIVE

The 3 Rules of Electricity Nobody Taught You

JCR Productions Electrical Training · 501 views

LIVE

8 Wire Stripper Features Everyone Should Know

LRN2DIY · 4.3M views

LIVE

Sub Panels Explained - Why are neutral and ground separated?

The Engineering Mindset · 2.8M views

LIVE

7 Things I'll Never Do As An Electrician

Backyard Maine · 1.3M views

LIVE

Electrical Wire Color Coding Used By Electricians

Electrician U · 840K views

LIVE

🚨 PLÖTZLICH ESKALIERT DIE RUNDE! Lisa Eckhart sagt EINEN SATZ – PUBLIKUM RASTET KOMPLETT AUS!

Scharfer Blick · 31K views

LIVE

Underground Conduit Mistakes Every Electrician Should Avoid!

Electrician U · 174K views

LIVE

What’s the DIFFERENCE Between a Load Center and a Panelboard? 🤔

Electrician U · 45K views

LIVE

What Surge Protectors Actually Do (and What They Don’t)

Electrician U · 207K views

LIVE

10 Mistakes DIYers Make in Electrical Panels

Backyard Maine · 764K views

LIVE

5 Tips for Electricians working in Residential Remodels

Electrician U · 167K views

LIVE

My Dream Power Hammer Restoration! Part 10

Alec Steele · 478K views

LIVE

WIRENUTS - Why Are There So Many, and Why You Should Care...

Electrician U · 157K views

LIVE

I Had a Loose Neutral Connection! Here's How I Found It

Smarter Sparky · 155K views

LIVE

Side Work: Is It Worth It?

Electrician U · 171K views

LIVE

10 Common Mistakes DIYers Make In Circuit Breaker Boxes

LRN2DIY · 3.7M views

YouTube, with the door locked.

Aegis plays a clean stream instead of YouTube's player, so pre-roll ads, trackers, and fingerprinting never ride along. Drop Shields any time if you want the official player back.