  • @Alex-01865 · 1 month ago (edited)

    Wire nuts installed properly, stripped evenly, insulation lined up, then twisted until the visible insulation turns 2 or 3 times, no bare copper visible, &nbsp;provides a far superior bond (more contact) &nbsp;between the splice and the wire nut, resulting in less damage to the splice, less wasted time! &nbsp; Don&apos;t take my word for it, dissemble and inspect a properly done wire nut and a pre-twist, might be surprised! 56 years in the trade, never called back for a single failure! State electrical inspector / Electrical contractor

    5

  • @steveurbach3093 · 7 months ago

    On your &apos;rock and roll&apos; segment. PAY ATTENTION to the strippers size markings. One side may be for Stranded and the other for Solid. They are not the same hole.

    82

  • @mattb9664 · 7 months ago (edited)

    I had a 2008 New Construction in NJ - every single outlet and light switch had the &apos;backstab&apos; connector used. &nbsp;We were still on incandescent bulbs back then, and I remember the lights being just a tad duller than they should have been. I upgraded the switches to blade-style- and I made sure to use the regular j-hook method to secure the wires. &nbsp;When I turned the lights on, I suddenly had full unrestricted current being made available to the incandescent bulbs, so they were full brightness. &nbsp;Using those backstabs is the same as using smaller sized plumbing with PEX B fittings everywhere, which chokes the water down even more. &nbsp;<br>Glad we got rid of that house and now have a bullet proof 1975 home.

    22

  • @djp_video · 7 months ago

    The electrician that wired my home (built in 2015) for some reason did something really weird. One circuit first goes to a GFCI outlet in the garage, then comes back to the utility room (coming off the Load side), where the main load center is located, and feeds a receptacle for the (tankless) water heater and water softener. It then heads to the back yard to feed the receptacle by the back door, and then back to the front again to feed the receptacle by the front door. Not only is it a lot of needless criss-crossing of the house, it also means I get cold showers when rain falls on an extension cord in the back yard that feeds a heated pet bowl and trips the GFCI. It took me a while to figure out how it was wired the first time it happened. <br><br>One day I&apos;ll get around to fixing it, moving the exterior receptacles to their own circuits, each with its own GFCI. <br><br>The sad thing is that he actually used more wire doing it this way than he would if he had done it right, by at least double. And there&apos;s plenty of space in the load center for more circuits. Makes me scratch my head...

    80

  • @thezombie7839 · 7 months ago

    I already like this channel a lot, but you just earned major bonus points if those are your CDs.

    30

  • @rickmelcher1351 · 7 months ago

    The first one you mentioned is so important, when I was teaching my students in the electrical course, I would show them how many times a nicked wire could be bent back and forth before breaking versus a non nicked wire - I think I got through to them!!!!

    28

  • @Ezees23 · 7 months ago (edited)

    I had a family friend that called me about their outdoor outlets not working as they were trying to use a corded trimmer and leaf blower. I came over and searched and searched for a broken wire or electrical fault somewhere between the panel and branched circuits - even looking in the attic and crawl space. I&apos;d already spent over an hour on a frustrating &quot;friendly call&quot; (ie, meaning a free &quot;favor&quot;). It turned out to simply be tripped GFCI receptacle in the bathroom (out of their 2-1/2 bathrooms) - one that fed the whole outdoor receptacle circuit that had tripped when the wife tried to use her hair dryer. All of that could have been avoided if any one of the original electricians or helpers had taken the time to simply use one of the several &quot;GFCI Protected&quot; stickers that came inside the box of nearly every GFCI receptacle made to indicate that the downstream receptacles were GFCI protected, FFS.....

    12

  • @PrinceofPeanuts · 7 months ago

    it wouldnt be a backyard maine vid without talking about backstabbing, which is what your local building dept does to your back!

    10

  • @jaywhite1850 · 7 months ago

    I’m just an avid diy’er, but to extend off of number 6, don’t ignore loose outlets. Your plugs should feel secure when plugged in. There shouldn’t be any looseness or sagging. That’s a sign of worn outlets and poor contact between the plug blade and the outlet’s internals. I’m in the process of switching out a bunch of my worn residential outlets with commercial grade.

    8

  • @mherde1072 · 7 months ago

    Concerning the part over the backstab connection / the spring-loaded connector: <br> <br>Where I work, the electrical safety body VDE, as well as the organisation responsible for training and licensing electricians (IHK), recommend the spring-loaded connector over screw terminals. The reasoning lies in the way the connection is established. The wire is pushed onto a connector plate by a piece of metal. When pushing in the wire, the metal is only deformed elastically, which means that the deformation applied to it is so small that it does not affect the metal’s permanent shape (that would be plastic deformation). That means that after removing the wire, the metal piece will always return to its former shape, no matter how long the wire was in the terminal. <br> <br>That guarantees a predefined contact pressure on the wire. This means the manufacturer of a terminal connection can make sure that, in practice, an inserted wire will be connected with the pressure he specifies based on his product testing, which with a screw terminal would only be possible by using a special torque screwdriver. <br> <br>But since the metal holding the wire in place is only deformed within the elastic range, it will never adjust to the wire pushing it. This means that despite age and micro-vibrations caused by a wire when it gets hot, the connection will always keep the same strength. Screw terminals, on the other hand, are usually not secured against that phenomenon. That means no matter how tight the screw was, there is nothing preventing the screw from slightly turning over time as the wire vibrates and expands and contracts under different temperatures. <br> <br>If, for example, the wire slightly expands, forcing the screw terminal’s screw slightly outwards, there is no force retightening the screw to the wire after it contracted again. In the spring-loaded connector, however, if the wire expands, it pushes the metal piece holding it further out. But as it shrinks again, the metal piece follows it, keeping the original pressure on the wire. <br> <br>It is very common in my experience to find screw terminals of circuits with high loads to be looser than those of ones with low load. That is why the spring-loaded connector is often referred to here as a maintenance-free connection, as the only thing that could over time increase the connection’s resistance is oxidation, but that is usually negligible.

    2

  • @slushbilly5893 · 7 months ago

    I agree with #4. Trying to find which GFCI that is feeding the dead outlet can be a pain. Just put a dedicated GFCI at each location would be easier but contractors try to save every penny.

    16

Up next

LIVE

10 Mistakes DIYers Make in Electrical Panels

Backyard Maine · 858K views

LIVE

7 Strange Electrical Tricks (That Actually Work)

Backyard Maine · 319K views

LIVE

7 Things I'll Never Do As An Electrician

Backyard Maine · 1.4M views

LIVE

The Most Dangerous Wire in Your Home

Backyard Maine · 194K views

LIVE

12 Things Electricians NEVER Allow in Their Own Homes — And Most American Houses Have Them

USA Home Build · 5.7K views

LIVE

The Hidden Code Rule Almost Everyone Misses.

Backyard Maine · 264K views

LIVE

Avoid These 5 DIY Electrical Mistakes

Everyday Home Repairs · 996K views

LIVE

7 FATAL Wiring Mistakes Most DIYers Don't Know They Are Making | Most Are Guilty of 3

How To Home · 12M views

LIVE

Homeowners Don't Know This Dangerous Circuit Exists!

Backyard Maine · 244K views

LIVE

9 Electrical Hacks (You'll Actually Use)

Backyard Maine · 361K views

LIVE

The Shocking Reason Why Your Outlets Are Installed Upside Down!

How To Home · 1.3M views

LIVE

9 Electrical Myths (You Should Not Believe)!

Backyard Maine · 187K views

LIVE

Why Don't People Know This About Electric Bills

Backyard Maine · 432K views

LIVE

I Had a Loose Neutral Connection! Here's How I Found It

Smarter Sparky · 267K views

LIVE

You’re Probably Using Wire Strippers Wrong

Backyard Maine · 1.2M views

LIVE

8 Wire Stripper Features Everyone Should Know

LRN2DIY · 4.6M views

LIVE

10 Common Mistakes DIYers Make In Circuit Breaker Boxes

LRN2DIY · 3.8M views

LIVE

I Discovered This Hidden Wiring Trick In An Old Forum!

LRN2DIY · 1.3M views

LIVE

This Kitchen Outlet Nearly Caught Fire — Here's What Went Wrong

FixItWithFil · 278K views

LIVE

This Connector Might Change the Way You Work (If You Let It)

Electrician U · 247K views

YouTube, with the door locked.

Aegis plays a clean stream instead of YouTube's player, so pre-roll ads, trackers, and fingerprinting never ride along. Drop Shields any time if you want the official player back.