Customer Fired Other Company! Can I Figure This No Cooling Out?
1.2M views · Aug 13, 2024 · People & Blogs
Comments · 682
@46fd04 · 2 years ago
"...he's just tryin' to get by." Owner probably says that every summer LOL
41
@j.t.johnston3048 · 2 years ago
The bad cap on the one fan motor kept it from starting properly. Once the other fan started, it was pulling air back through the other fan causing it to start pinwheeling backwards.
244
@YTsux24-7 · 2 years ago
"I know it's old, I know it needs replaced, but if i can get seven more years out of it before i retire, I'd appreciate it, mang." <br>Every time...
335
@Pikolika · 1 year ago
Takes courage accepting a customer that fired another company. Customers like that are always trouble atleast for me
57
@Kitsune_Rick · 1 year ago
No maintenance walkways on a commercial rubber roof ?!?<br> Jeez that is just asking for accidental rips and tears from contractors.
12
@rumblertag1419 · 1 year ago
yeah I agree hand over the fan before I even drop my bag down yet lol
17
@Glenneilson-t8w · 9 hours ago
The other guys put the bad compaciter .in the last clean. So thay could shake him down for a new unit.
@gradyrm237 · 2 weeks ago
two sides to every story. Not defending the other company, I just never take one man's story as truth.
@pauljanssen7594 · 2 weeks ago
I was working for this ministry, they couldn't figure out why the unit was blowing fuses. That two companies come out to check it and they said you have to replace the whole unit it's worn out. Ask me to take a look guess it didn't need to replace but it had a couple more good years left in it, I asked him which fuses are being blown it was the main ones coming up to the unit, 3-100 amp fuses, then I looked at the other fuses the ones for the compressor and the ones for the heating unit. I asked him where they running the heater at the same time they said no just the compressor, so I looked at the junction block sure enough for lightning strike had damage the unit it was conducting electricity like a big resistor that's why I took 5 to 10 minutes before it would blow the 100 amp fuses. So I did a little trick I had some leftover parts from something else and I tied all the wires together very carefully. Triple taped everything, thus the unit is still working has been for several years. It's called do the math folks 40 amp fuse cannot blow 100 amp fuse that was the compressor fuse. And the heater fuses for 60 amps and they were not used when they were not turned on.
@stacihess9378 · 1 year ago (edited)
I've seen this twice. Both on single fan rtu's. Unit was tripping on high head. Replaced cap, spilt condenser and cleaned. Unreal how much crap gets between those split coils. Also, labeling refrigerant removes a ton of headache. Nice work!
11
@tomh3652 · 2 years ago (edited)
Some companies you just cant trust. The one that came to my house to check my 21 year old Trane 3 ton unit told me it could not be fixed. But the next company showed up found a pin hole leak in the copper line fixed it in like an hour saved me from getting a new unit for now he said it could last a few more years.
40
@sleezye100 · 19 hours ago
It’s it’s an original part. It’s a 5.5. It needs a 5.5 capacitor if it’s a 7.5 motor and you’re running on a five capacitor it will run backwards.
Up next

Customer Wanted a Second Opinion... Here's What I Found.
JustintimeHVAC · 126K views

Nope Nope Nope the service call I refused
HVACR VIDEOS · 208K views

DIY AC Troubleshooting Guide | Diagnose Your AC Yourself
Dave Wirth · 1.4K views

Sometimes We Need to Fire The Customer!
HVAC GUY · 209K views

No A/C - Everything Failed! American Standard, Stick to Plumbing
Davevid · 19K views

I Got FIRED From My First HVAC Job… | ECM Fan Motor Replacement Vlog #hvac #hvaclife #hvactech
Joe Romero | DFW HVAC Expert · 3.7K views

HVAC Scam Exposed: What They Don't Want You To Know
steven lavimoniere / PLUMBING HEATING & AC VIDEO'S · 26K views

When Mike Tyson Faced a Beast
PEAK MEDIA · 2.4M views

This AC is Less Than a Year Old.. And it Already Has a Major Failure
JustintimeHVAC · 12K views

New Install. Angry Customer. What Did They Miss?
HVAC AO · 42K views

It's Over: Bonds COLLAPSE to WORST Levels Since 2002 - Netherlands BANS Microsoft
House of El · 75K views

Putin's CROWN JEWEL is GONE: Russia's TU-95 Fleet DESTROYS Itself
The Geo Network · 68K views

They Walked Off The Job… Then I Found THIS 👀
JustintimeHVAC · 392K views

I Scrapped 13 MACHINES to Prove a Point: STOP BUYING These Brands!
how-2-repair.com · 976K views

This part costs $10,000 PER DAY until FIXED
Glease Man · 738K views

THE OTHER COMPANY COULDN'T FIGURE THIS ONE OUT
HVACR VIDEOS · 208K views

This HVAC Diagnosis Fools A LOT of Technicians... Can You Find It? | Real Life Service Calls |
HometownHVAC · 19K views

When Young TYSON Fought a Freak of Nature…
Boxing Empire · 794K views

Even a Pro Had Trouble Figuring This One Out!
HVAC GUY · 67K views

IT'S TIME FOR A CHANGE
HVACR VIDEOS · 41K views