A BIG advantage of Wagos that should have been mentioned: they don't work-harden solid wire. You can redo a Wago connection a dozen times with no damage to the wire, but you get only a few with wire nuts before the wire breaks off and you don't always know when the wire is about to snap. I do like that you pointed out how wire nuts are much more skill-dependent, which is another plus for Wagos. The only disadvantage of Wagos is their cost.
379
@TwilightxKnight13 · 1 year ago (edited)
As an electrical engineer, we did a huge termination study and if properly installed, per manufacturer's directive, ALL terminators (wire nuts, push ins, lever locks, polaris, etc) are equivalent (short of soldering/cad welding). Most wire nut manufacturer's do not require pre-twisting, and some of them specifically instruct you not to do it as it can interfere with the design of the spring cone inside. He is exactly correct that virtually all arguments that electricians have for or against certain installation methods and equipment are not based on accurate data. The most common complaints stem either from a perceived preference (usually anecdotal) that is not supported by the data, or based on poor installation techniques that resulted in faulty connections.
159
@SilverBullet93GT · 1 year ago
hr department: we are here to talk about your termination<br>electrician: ya, what about it?
109
@C6Z06J · 1 year ago
Two types of people. People that haven't use Wagos yet. And people that love using Wagos. I use them on everything. My home wiring, my 3d printer fan upgrades, in automotive test situations before i hardwire. Simply an incredible tool
74
@stephenm8107 · 1 year ago (edited)
I'm not an electrician. I am a DIY home guy, the bane of professionals everywhere. That said, I have done a lot of wiring...for a DIYer. Multiple buildings and renos, done with wire nuts. I can tell you that, while they don't require a lot of skill, there is skill to doing them right and a home owner is MUCH better served <s>in my opinion</s> with the WAGO 221s. I have enough experience that I am comfortable doing wire nuts for any project... but I've switched to the 221s because I don't need to "get it right" for it to be safe and solid. From a DIY perspective, they are 100% amazing. Oh! and they also make going from solid to stranded fool-proof. Not a super common use case, but absolutely great when needed.
64
@jonathanmerry3800 · 10 hours ago
Thank you!!! I’m at UEI in Oceanside 4 weeks in, really like your advice
@Hybris51129 · 1 year ago
As a DIY guy just starting electrical projects I like the Wago's over the nuts simply because if for some reason I do mess something up I can move stuff around without causing damage to the wires. So far I haven't had to work in any sort of tightly packed boxes so the lever lifting hazard hasn't been a factor but your suggestion of taping them down sounds good.
40
@Conqueef-tadoor · 1 year ago (edited)
I just converted an entire building of T8 fluorescent light fixtures to LED tubes. I found Wagos to be the best connectors for that purpose.
24
@davidkrellner2251 · 1 year ago
Lever wagos have came in clutch more times than I can count. Specifically in old houses and signs which are both notorious for short wires. Lever wagos make extending short wires an easy job
7
@Stefan_Van_pellicom · 1 year ago (edited)
Over here (Belgium) we abandoned wire nuts during the 70’s altogether. Wago has been the standard for decades now. The ones with levers (221 types) are only used when stranded wire is involved due to their price. The 2273 is used for everything with solid conductors. The are available in 2,3,5 and 8 conductors.
15
@Robnord1 · 1 year ago
I love the Wago 221s. Just ordered a box of 80 of the 2 conductor butt type to refill my assortment. Expensive, yes, but in my RV repairs where working in tight places mostly with 12V conductors they are a godsend.
55
@noelv1976 · 8 months ago
I've been a Wago believer recently. Started a new job as a maintenance technician for a fast food restaurant and the amount of ballasts I've replaced the past few months is insane. The techs before me installed wagos and holy crap it's so much easier to disconnect one wire from a wago instead of unscrewing a wirenut just for one wire.
4
Up next

Splices And Terminations That Fail Code In The 2026 NEC
Electrician U · 98K views

Underground Conduit Mistakes Every Electrician Should Avoid!
Electrician U · 192K views

An Engineer tests Wago Connectors. Are they any good?
Electromagnetic Videos · 110K views

What are the most common electrical mistakes made ? for a Wall Rough
Tools And Tactics · 328K views

How to Read HVAC Wiring Diagrams Without Getting Lost
Hvac Tom · 147 views

Solar Is Much Simpler Than You Think! | Off-Grid Solar Explained
Smarter Sparky · 1.5M views

MC Cable vs AC Cable: Are They the Same Thing?
Electrician U · 82K views

Are Lever Connectors a New Code Issue? (Box Fill Explained)
Backyard Maine · 595K views

New Tools, Tech, and Gear Every Electrician Should See
Electrician U · 56K views

What Pros Know About Screws That Beginners Don't.
Five Duck Studio · 10M views

I Had a Loose Neutral Connection! Here's How I Found It
Smarter Sparky · 266K views

Your Electrician Doesn’t Want You To See These New Tools!
How To Home · 245K views

Why Electricians Are Losing Their Minds Over This New Bender
Electrician U · 148K views

Milwaukee doesn’t make this CAT6 tool, so I did
Analytical Horsepower · 355K views

Everything You Need to Know About Electrical Panels
Electrician U · 175K views

7 Things I'll Never Do As An Electrician
Backyard Maine · 1.4M views

Electricians Hate Me For Sharing These Tools
LRN2DIY · 369K views

Why Does America Use 60 Hz While Europe Uses 50 Hz?
Weirdward Bound · 1.6M views

9 Electrical Hacks (You'll Actually Use)
Backyard Maine · 360K views

The Ultimate Guide to the Wago 221 Inline Connector
eFIXX · 293K views