Terminating/Testing Network Cables - CAT 3, CAT5, CAT6, CAT 7, CAT 8
1.2M views · Oct 9, 2019 · Education
Comments · 941
@lyfandeth · 6 years ago
Cat5 "UTP" stands for <b>unshielded</b> twisted pair. Not "universal". And STP is, conversely, <b>shielded</b> twisted pair, referring to an RF shield wrapped around the wire bundle, under the outer jacket.
146
@EsotericArctos · 7 years ago (edited)
Gigabit Ethernet uses 8 wires (4 pairs). Only 100mbits and 10mbits ethernet leave 2 pairs unused, unless Power over Ethernet is implemented, then all 4 pairs are used again.<br>It is critical to get the wiring of all 4 pairs correct for Gigabit or 10Gigabit ethernet. It is also critical for systems that use Power over Ethernet.<br>Telephone lines only use one pair, they do not use two pairs. Telephone uses a multiplexing system and only needs two wires (one pair) to both send and receive. If you only use 4 wires ( 2 pairs) as described, you will only get a maximum of 100mbits speed.<br>:)
268
@michaeldoit1 · 5 years ago
Don’t untwist pairs when doing the jacks , only for the plugs
32
@thetechstop3875 · 7 years ago (edited)
Here’s something I would’ve added in, and done differently. you want to keep the twist in the cable as much as possible, or else they would not certify if tested. The best way to punch down a keystone is to leave them twisted, and make a small gap with your fingernail. It allows the pair to go into the keystone Slots, and is much easier to terminate since they won’t slip out. Also, it means the twist stay in the cable
195
@karlbrown3214 · 3 years ago
Lo impact is for keystones and punch down blocks with the same type pins so you have less chance of damaging the pins and the tabs. Hi impact is for your traditional 66 block type connections and uses more force to get to the board and cut the wires. <br><br>I have done some government wiring years ago and we had to certify each wire for it's speed capabilities, it would give you a pass or fail but also numbers for the speed it could transfer data. If you had too much untwisted wire the capabilities of the data cable would be diminished.<br><br>Great video and a lot of useful information, I always enjoy your videos.
21
@jenniferwagner4595 · 5 years ago (edited)
A quick tip, once you expose the wires, use the string and pull it back to slit the sheaf. This prevents nicking of the twisted pairs. I usually use my scissors and cut into the first inch or so of the cable, find the string and pull it back. There are pass thru versions of the rj45 plug that make it easier to verify the pairs are correct. The crimper than cuts the excess cable.
41
@GerbenWijnja · 4 years ago (edited)
Great explanation of the keystone jack, very informative. <a href="https://www.youtube.com/watch?v=rZKVPuInQ2Y&t=190">3:10</a> "With ethernet you're only using 4 out of these 8 wires." That's partially correct. With 10/100 Mbit, you use 4 wires: 1 pair for TX and 1 pair for RX. But 1 Gbit uses all 8 wires: 4 bidirectional pairs. You can try this yourself by only connecting the 4 wires mentioned in the video (pin 1, 2, 3 and 6) and then connecting for example your laptop to your router. It will show that it's connected at 100 Mbit instead of 1 Gbit.
49
@chadhidalgo5763 · 7 years ago
The keystone has a "puck" that provides a little wider footprint for punching down and it protects the tab from being broken. It can be difficult to get the keystone jacks into and out of the puck when they are brand new, but it does help.
15
@MrThinking4myself · 5 years ago
Love your channel. Just so you know, a phone line is only two conductors. The four pins are for locations with two phone lines. The "full duplex" capability of telephones is really quite a clever design, but it uses two conductors. <br><br>Also, gigabit ethernet uses all 8 conductors, as does POE Power over ethernet.<br><br>All that said, your videos are great 👍
54
@ToxicMinecraftV2 · 1 year ago
I just started my first day of low voltage definitely have a lot to learn still. I was able to successfully terminate and crimp a couple rjs (after going at it for like 10 minutes). But i did finally get it but still need to work on consistency. Hopefully watching this will help me get better at doing my job.
2
@SnackManJ · 7 years ago
Great video. A couple of updates to your information. The brown and blue pairs ARE used in networking for several things, not the least of which is PoE. Second, Telephone is full duplex over ONE twisted pair, the second pair is for a second line. I believe the Kevlar string is for strengthening the cable for pulling, though it is a convenient jacket splitter. The Crimp tool has two blades, one for scoring the jacket and one from cutting the ends off straight. Last, but not least, for electricians who are running the wire, be careful not to kink the wire. A kink will degrade or prevent the signals, and it is recommended that the wire be at least 12" from power wire when running parallel.
75
@DrD6452 · 4 years ago
Phones only use 2 conductors. Always use the rip cord and strip the jacket back. Wires almost always get nicked during the score. Gigabit and PoE use all 8 conductors. When wiring jacks don't untwist the wires as the twist needs to remain as close as possible to termination points in order to pass certification.
3
Up next

Episode 46 - CRAFTSMANSHIP - Mastering Your Craft
Electrician U · 50K views

How to Become a Network Cabling Technician Training | Low Voltage | Part 1 | Bridgecable.com
Bridge Cable · 268K views

I Tested EVERY Ethernet Cable... You WON'T Believe the Results!
landpet · 2.1M views

How to Wire an Electrical Panel - Good Workmanship
Electrician U · 493K views

Stop Wiring RJ45s WRONG! (EZ vs. Pro Method)
Ultimate Tech Hub · 492K views

The Top 7 Things You Should NEVER Do With Ethernet Cable - 2024 Recommendations
trueCABLE · 39K views

Wiring Ethernet Extensions: How to Fit Sockets & Make Patch Leads
ExplainingComputers · 647K views

Solar Is Much Simpler Than You Think! | Off-Grid Solar Explained
Smarter Sparky · 1.5M views

Every Networking Technology Explained In 31 Minutes!
Mr. Byte · 164K views

How to Terminate Ethernet Cables
Crosstalk Solutions · 748K views

This Budget Network Cable Tester is AWESOME! - Noyafa NF-8209S
Cameron Gray · 193K views

Cat 6 vs Cat 7. What is the difference
Mike Faucher · 450K views

Stop Buying the Wrong RJ45 Connector!
Ultimate Tech Hub · 36K views

MC Cable vs AC Cable: Are They the Same Thing?
Electrician U · 83K views

Selecting the Correct RJ45 Connector
trueCABLE · 117K views

How To Bend EMT Conduit/Tubing - School Edit
Electrician U · 117K views

How to Terminate Cat6 Shielded Cable with an RJ45 Connector
Angie Durbin Creates · 879K views

How to Punch Down a RJ45 Cat6A Keystone Jack
Discount Low Voltage · 572K views

Ethernet Cables, UTP vs STP, Straight vs Crossover, CAT 5,5e,6,7,8 Network Cables
PowerCert Animated Videos · 3.2M views

This Connector Might Change the Way You Work (If You Let It)
Electrician U · 247K views