HVAC: LG MULTI V Heat Pump Error Code CH42/CH43 Follow Up Repair (LG Heat Pump Not Cooling) LGMV
15K views · Jun 8, 2024 · Science & Technology
Comments · 114
@jimbeam275 · 2 years ago · pinned
I love repair communities that come together and share information with each other. Everyone wins, a beautiful thing
27
@oldmetalguy4577 · 2 years ago
Jumper man Tech: I need something to do that fills up all this free time I got, and my weekend.<br>Herd of LG's: Hold our beer, we got this.<br><br>LOL!
2
@yzhang8629 · 2 years ago
Looks like this customer is your cash cow, thanks to their choice on LG
19
@stephenbordieri · 2 years ago (edited)
The paste flux and bare roll of 56% is my go to and is way easier to use, especially in a situation like this. No messing around with not being able to bend the rod or the flux flaking off<br><br>Get yourself some 1/2" or even 3/4" evacuation hoses with core removal tools, makes repairs/service on VRF go way quicker/smoother.
3
@avi-tar2827 · 2 years ago
Love the view. Reminds me of my days doing Chicago work. Nice job on the torch with the high-content silver rod, too. Good call as you needed all the capillary action you could get in that tight space. Silver loves to flow like lead does.<br><br>Too bad the compressor ate itself...you'd be the weekend hero otherwise.
3
@BartlettTFD · 2 years ago
What a terrible work location! I couldn’t handle that high altitude location either! GREAT workmanship👍👍
2
@HvacAce · 2 years ago
This might be late, but I use to share a LGMV module with a co-worker and we would constantly run into that "Time out issue". What seemed to work for us was after disabling "switch to mobile data", completely power cycling the system seemed to solve it. Also while there arent sight glasses on the compressors, there are oil sensors that you can view on the LGMV app under "cycle & valves info" for each compressor, where if its green it has an appropriate amount of oil and if its grey the system will use its "smart oil management" to try and get the oil back to the compressor. Lg recommends enabling forced oil return on systems where compressors died due to low oil or unknown causes. Ive only really worked on Multi V 5s so im not sure how this translates to 4s. I think it should be the same , but thought it would be helpful to pass off anyways. I enjoy the content, keep it up man
1
@lowrybrock8272 · 2 years ago
At this rate a couple more years of working here and you can retire! It’s pretty disappointing to see the units, which I’m sure they paid a pretty penny for and to install, fail at the rate they are. Makes me want to avoid any LG hvac products. Hello from sunny Florida! Love your videos and try not to miss them. Take care and be safe out there.
1
@ronnym1977 · 2 years ago
Way to stick with it.<br>Your troubleshooting and diagnostic skills are excellent.<br>Good job.
4
@ruslan-lf4wq · 1 year ago
very useful video, a lot of use, tell me what kind of welding you have and what brand it is, thank you
@randomyoutuber6992 · 8 months ago
JM ,You need help on the weekends? I have experience in the field
@blakeshull9316 · 2 years ago
Ive had these valves actually leak on the stem as well. Take the coil off when you leak check!
Up next

HVAC: LG Multi V Not Cooling/Error Code CH75 (LG Multi V Error Code CH 75 Troubleshooting & Repair)
Jumper man Tech · 11K views

HVAC: Troubleshooting LG MULTI V Error Code CH35 (ODU Excessive Pressure Drop Of Low Pressure) LGMV
Jumper man Tech · 7K views

Your Fridge Is Secretly Heating Your Kitchen
LaplaceLAB · 35 views

HVAC: LG MULTI V Heat Recovery Heat Pump Not Cooling/Not Heating (Error Code CH 42) Error Code CH43
Jumper man Tech · 9.4K views

HVAC Service Call: LG Multi V No Air Flow (LG Concealed Duct Cleaning) Ducted LG AC Not Cooling
Jumper man Tech · 14K views

Heat Pump Blowing the Wrong Temperature? Understand the Reversing Valve
Hvac Tom · 656 views

Recharging my R290 mini split air conditioner and heat pump
MartinsDIY · 13K views

Heat Pump Designer Reveals What Everyone Gets Wrong
Refurb And Retrofit Magazine · 43K views

HVAC: LG MULTI V Not Heating Follow Up Service Call (LG Wired Remote Controller Blinking On And Off)
Jumper man Tech · 8.1K views

LGMV HAVC TROUBLESHOOTING LOW REFRIGERANT
D2D NY Real World HVAC Simplified · 13K views

Installation of 24 Carrier conventional ducted split air conditioning units
LF Gaivota Conforto térmico · 28K views

HVAC: Johnson Controls RTU Not Cooling Elevator Mechanical Room (Johnson Controls Roof Top Unit)
Jumper man Tech · 72K views

HVAC: York RTU Not Cooling Properly (York Packaged Roof Top Unit Troubleshooting And Repair)
Jumper man Tech · 19K views

HVAC Service Call: LG MULTI V Not Cooling (LG Multi V 5 Error Code CH26) VRF Troubleshooting/Repair
Jumper man Tech · 12K views

HVAC: Omega Hybrid Water Source Heat Pump Had Major Problems! Troubleshooting, Diagnosis & Repair
Jumper man Tech · 6.8K views

HVAC: LG MULTI V Refrigerant & Oil Acid Testing (Nu-Calgon Oil Test Kit/Qwik Check 2-Second QT2000)
Jumper man Tech · 10K views

HVAC Service Call: LG MULTI V 4 Error Code CH26 Repair (Inverter Compressor Overcurrent) CH29 Error
Jumper man Tech · 10K views

HVAC: LG MULTI V INVERTER S startup. My first time working on VRF systems.
Rookie Refrigeration · 57K views

Scientists Said This Wave Was Impossible
Veritasium · 889K views

HVAC: LG Multi V Not Heating/Cooling (LG Simple Wired Remote Controller Keeps Turning On And OFF)
Jumper man Tech · 10K views