High Voltage Issues Lead to More Problems! #hvaclife #hvacguy #hvacarmy
68K views · Sep 14, 2024 · People & Blogs
Comments · 310
@stevenkirby7478 · 3 months ago (edited)
It never ceases to amaze me that builders don't, as a matter of practice, put a light in the attics, especially with an ac unit in there.
4
@althompson3332 · 2 years ago
You did the right repair. Look on the bright side . You stopped a potential fire hazard. You did the Right thing.
34
@barrwall661 · 2 years ago
Watching your videos will earn yourself the equivalent of a bachelor's degree in HVAC.
57
@1964davidsable · 2 years ago
I'm an electrician and sometimes dive into HVAC. You should consider getting insulated tap connectors. It would have saved you a lot of time instead of using those split bolts. The tap connectors need nothing. Fully insulated. A allen wrench to tighten. It would take 2 min. to make that connection.
68
@mddale · 2 years ago (edited)
Just seeing you retrieve that screw using the flashlight magnet was cool. The simple things I never think of. I was impressed by your confidence to close up the cabinet before knowing everything was good. Ha!
22
@ncooty · 1 year ago
That van set-up is super efficient and organized. I really admire it.
12
@Mike-q2w4j · 2 hours ago
It done blowed up
@Qualityservicesbcs · 2 years ago
That wall looks like the compressor blew the charge out .
6
@davidsharkey3483 · 2 years ago
If the manufacturer wasn’t so cheap they could give you a terminal block ,
3
@gregeconomeier1476 · 2 years ago
Those folding ladders are handy by they sure are heavy.
24
@justinwallace390 · 3 months ago
I always see you toting around that Little Giant ladder. I own one for my personal residence, but we have a love-hate relationship. I love it because it is so versatile, but hate it because its so damn heavy. I usually carry a 6 foot and 8 foot fiberglass ladder on my service vehicle. Of course we keep an extension ladder in the shop when we get commercial work.
2
@shelshele · 2 months ago
Rain made you change how you troubleshoot, use your umbrella lol
Up next

Condenser Fan Motor Was Not Turning. And Impossible Access To Air Handler! #hvacguy
HVAC GUY · 47K views

Other Tech “Thought” It Was The Compressor! #airconditioning #hvacguy #hvactrainingvideos
HVAC GUY · 81K views

Low Voltage Problems - Repairing And Causing Them At The Same Time!
HVAC GUY · 20K views

Handling A Mistake, And Making It Right! #hvacguy #hvaclife
HVAC GUY · 34K views

Day in the life HVAC service calls
CREATIVEHVACR · 5.7K views

Not Every Day That The Customer Tries Fixing It Himself! #hvacguy #hvaclife #hvactrainingvideos
HVAC GUY · 38K views

Halloween Day Brings A Blower That Wasn’t Running! #hvacguy #hvacarmy #hvactrainingvideos
HVAC GUY · 17K views

When Young TYSON Fought a Freak of Nature…
Boxing Empire · 790K views

HVACR: Perlick Glycol Chiller FREEZING UP! Troubleshooting/Repairing Commercial Refrigeration System
Jumper man Tech · 6.6K views

Germany Lost D Day in the First 10 Minutes — Before the Beaches Were Stormed
WW2 Stories Archive · 185K views

Going Behind A Maintenance Man! #hvaclife #hvacguy #hvactrainingvideos
HVAC GUY · 18K views

They Found a HUGE Root Problem at This School!
Keep_itflowing · 5.8K views

HOW DO TRAINS ACTUALLY START? The Physics of Moving 100,000 Tons
Vintage Trains · 269K views

Customer is PISSED and There Is NOTHING I Can Do
Koolin’ with Krauss · 105K views

I Couldn’t Just Leave It Like That! #hvacguy #hvaclife #hvactrainingvideos
HVAC GUY · 24K views

Some Competitors Would’ve Replaced This System! #hvacguy #hvaclife #hvactrainingvideos
HVAC GUY · 44K views

This $7 EARTH BATTERY Generates FREE Power from Soil
Glen Pritchard · 499K views

Replacing a TXV That Was Locked Down! #hvacguy #hvaclife #hvactrainingvideos
HVAC GUY · 28K views

When they Put Young Mike Tyson against The Smash Machine
Boxing Game · 3.8M views

Neighbor Was Nice Enough To Trust Me To Fix Her AC! #hvacguy
HVAC GUY · 75K views

An Avoidable No Heat Call Causes An Expensive Repair!
HVAC GUY · 34K views

RESCUING AN ABANDONED FODEN RECOVERY TRUCK AFTER 10 YEARS!
Mr Hewes · 631K views

Step By Step Changing a 4 Ton Scroll Compressor! #hvacguy #hvaclife
HVAC GUY · 24K views

New Customer Complained Of His Blower Not Working! #hvacguy #hvaclife #hvactrainingvideos
HVAC GUY · 20K views

Polar King Walk in freezer electrical troubleshooting
Brandon HVAC-R · 546 views

OLDER R22 A.C CONDENSER FAN NOT SPINNING
steven lavimoniere / PLUMBING HEATING & AC VIDEO'S · 17K views