How to test Daikin PCB for Communication Faults.

22K views · Jun 25, 2024 · People & Blogs

Comments · 50

  • @Avidbrowser91 · 4 weeks ago

    A series for HVAC beginners/aspiring apprenticeships would be awesome

  • @brewaz · 1 year ago

    You are an inspiration, so many people will not share this type of information!

    7

  • @AdamCraig-s6s · 10 months ago

    If only we worked on the same equipment I’d be binge watching your stuff but i completely agree.

  • @MitchellMIller-db7gk · 1 year ago

    Hey Mitch, enjoying your video. Clearly explained and easy to understand with real world tests.<br><br>Keep them up, well done.

    2

  • @robalexander7348 · 2 years ago

    Explained well Mitch, &nbsp;so handy for the boys entering into the A/C game &nbsp; &nbsp; &nbsp; 👍

    1

  • @LKN-HVAC · 1 year ago

    Good information here Mitch! I just wanted to throw a couple of things out there since you live near the coast too....I found it odd the first Daikin mini split I installed the cable they gave me at the supply house was 14 ga stranded between indoor and outdoor but since I knew it had communications on one leg I thought it was odd not having a shielded cable and running together with AC line 😂. I spent much of my career also in the BAS building automation systems world so anything that communicated with DC especially if run in the same bundle with high voltage AC would create many issues and the longer the run the worse it can be. Daikin larger VRV in commercial/industrial applications recommend shielded and only ground the shield in the outside unit never both ends. Most DC communication wires in the BAS industry always state not to be within 2&quot; inches of AC line volts too and never run parallel and to cross at 90 degrees if close together. <br><br>I was going to also suggest a couple of things if you have intermittent com errors being near coastal area. Make clean connection metal to metal with good quality round crimp terminal connectors then apply die electric grease for long term protection from oxidation. Running shielded cable between the indoor and outdoor unit and terminating shield at outdoor unit only cannot hurt to drain any unwanted signals from terminal 3 communication wire. Also if having intermittent comm issues redo both terminal grounds and system unit grounds indoor and out to bare metal to metal than coat with thin layer of die electric grease if near coast. If long runs above 50 feet I would invest in the shielded cable between in and outdoor just in case! 😉<br><br>Of course you can have a weak comm driver that is getting ready to fail on the boards! <br><br>Very good video Mitch and just wanted to add my 2 cents and thoughts.

    1

  • @downunderboy100 · 11 months ago

    Great information mate thanks for the clear explanation

  • @HHK1090 · 2 years ago

    Really liked this video! Very informative. Thank you Mitch!

    2

  • @boldizsarnovak9037 · 2 years ago

    Really informative video! Thank you and keep up the good work!

    1

  • @juanantoniog5875 · 2 years ago

    Gracias por compartir sus conocimientos

    1

  • @john7017 · 1 year ago

    Also can use a 1 channel oscilloscope to see the communication packets...

    1

  • @WhispersofSnow-Rosevalley · 1 year ago

    Hey Mitch love the content learnt much from ya can you do this video for all other brands? Like mitsi fujitsu etc please

Up next

LIVE

Why Does This Keep Happening? ⎪Shocking Reason This Daikin Stopped Working! (U0 Fault Explained)

Mitch Attwood · 39K views

LIVE

Daikin NO COMMS (U4 / UF) — Outdoor PCB Was Dead… Then I Found This

Mitch Attwood · 9K views

LIVE

Daikin U4 Error — You Already Know What This Is

Mitch Attwood · 26K views

LIVE

HOW TO INSTALL A DAIKIN SUPER MULTI? | FULL INSTALLATION VLOG

PRIMAL AIR & REFRIGERATION · 11K views

LIVE

Daikin L5 Error Diagnosis & PCB Replacement | Fault Finding and Repair

Kavanair · 2K views

LIVE

The DAIKIN R32 Ducted Air Conditioner no one can seem to fix! ⎮ U0 Error

Mitch Attwood · 33K views

LIVE

What’s Wrong With This Daikin Inverter? | L1 Fault

Mitch Attwood · 8.7K views

LIVE

Daikin U2-02 Fault Fixed⎜The Cause Was Totally Unexpected

Mitch Attwood · 12K views

LIVE

We Started This Daikin AC Install MONTHS Ago… Here's How It Turned Out!

Mitch Attwood · 9.3K views

LIVE

Every Mini Split Part Explained — And How to Test Each One

Taddy Digest · 66K views

LIVE

I CAN'T BELIEVE that this has happened AGAIN!

Mitch Attwood · 10K views

LIVE

How to test Daikin EEV Coil (6 Cables).

Mitch Attwood · 7.6K views

LIVE

Five Head Daikin Mini-Split Troubleshooting PCB Board Non Functional. EP35

Nighthawk HVAC · 49K views

LIVE

Diagnosing Daikin E5 Error

Mitch Attwood · 36K views

LIVE

How to Troubleshoot Daikin VRV Inverter Boards

Mechanical Pros · 34K views

LIVE

Daikin FIT Commissioning for HVAC Beginners

Taddy Digest · 22K views

LIVE

Diagnosing Daikin U2 Error

Mitch Attwood · 37K views

LIVE

INSTALLING A DAIKIN R32 INVERTER MINI SPLIT AIR CONDITIONER

Mitch Attwood · 70K views

LIVE

Diagnosing Daikin U0 Error⎪2

Mitch Attwood · 37K views

LIVE

Daikin DZ17VSA Series Minisplit with Full Size Air Handler Not Communicating Intermittently. EP152

Nighthawk HVAC · 2.9K views

YouTube, with the door locked.

Aegis plays a clean stream instead of YouTube's player, so pre-roll ads, trackers, and fingerprinting never ride along. Drop Shields any time if you want the official player back.