How to test Daikin EEV Coil (6 Cables).
7.7K views · Jul 26, 2024 · People & Blogs
Comments · 16
@AbuOmarOagil · 1 year ago
The best video to explain the identification of the eev 5,6 wires. Thank you.❤
2
@HHK1090 · 2 years ago
Love this and the 5 cables video. Please do more videos like this, learnt so much from your videos. Thanks Mitch!
3
@aungthiha5050 · 2 years ago
Thanks mate. Please do more video on HVAC component troubleshooting.
5
@MayoMitch · 6 months ago
Why can I not find anything about this in their service manuals. Thank you for this video.
@craigladewig3158 · 2 years ago
There is a EEV checker on Aliexpress, also allows over voltage to potentially break a stuck valve loose. Used a similar device on a Samsung DVM system a while ago and the over volt managed to break the valve free - been working fine since then (touch wood)
3
@pedrosolares3085 · 2 years ago
Please do more high efficiency troubleshooting content
@pepzidoesit · 1 year ago
Nice! <br><br>Was troubleshooting an older Daikin Inverter RK24AXVJU model <br>Yesterday and checked out this component and on their service manual they mentioned continuity should be present 6-5 ect up to 6-1 . But no mentioned on what’s common so I was thrown off and just compared readings to an identical unit near by and got the same OL readings ,but makes sense with your breakdown.<br><br>Well anyways thanks for this 6 pin training! Still ordered the eev for car stock and will do this procedure and compare.
@pedrosolares3085 · 2 years ago
Thank you!
@EinsteinAirServices · 2 years ago
Thanks bro
@declankearney9353 · 7 months ago
Just wondering Mitch have you changed any eev valves on small splits with limited space I imagine it’s a dog of a job.
@CodyHVAC · 7 months ago
Does this only work for daikin or are most brands the same?
1
Up next

How to test Daikin PCB for Communication Faults.
Mitch Attwood · 21K views

EEV vs TXV Metering Device Operation, Efficiency, Additional Parts, & Evaporator Coil Function!
AC Service Tech LLC · 46K views

🔧How to check expansion valves before replacing them. Commonly found if the air conditioner repor...
ช่างสามัญประจำบ้าน · 98K views

Checking the Magnetic Pulse control of an EEV
East Coast Service Solutions · 38K views

Daikin L5 Error Diagnosis & PCB Replacement | Fault Finding and Repair
Kavanair · 2K views

We Started This Daikin AC Install MONTHS Ago… Here's How It Turned Out!
Mitch Attwood · 9.3K views

What’s Wrong With This Daikin Inverter? | L1 Fault
Mitch Attwood · 8.8K views

EEV Valves and Power Heads
HVAC is WIN · 23K views

The Electronic Expansion Valve Uncovered: A Comprehensive Guide!
Forever Tech English · 19K views

Who Thought Installing This Was a Good Idea?!
Mitch Attwood · 9.8K views

HOW TO TEST DAIKIN EEV COIL (5 Cables).
Mitch Attwood · 42K views

How to Troubleshoot Daikin VRV Inverter Boards
Mechanical Pros · 34K views

How To Diagnose Daikin VRV EEV Powerhead
Mechanical Pros · 9.9K views

Ducted Air Conditioning in an APARTMENT?! | Daikin Install
Mitch Attwood · 10K views

How to Work on Mini Splits?
Taddy Digest · 205K views

Daikin inverter | air conditioner Thermistor Failure Symptom
Bon Mj · 35K views

Five Head Daikin Mini-Split Troubleshooting PCB Board Non Functional. EP35
Nighthawk HVAC · 49K views

Testing an EEV
Samsung HVAC America · 47K views

Mastering Decay Testing With BluVac 3.0
measureQuick · 7.3K views

24-Year-Old Air Conditioner Finally Gets Replaced!
Mitch Attwood · 6.5K views