Are Zero Disruption Installs the Heat Pump Industry's Next Big Lie?
5.7K views · Jun 3, 2026 · People & Blogs
Comments · 56
@Leo99929 · 5 months ago
Something that not enough people think of: You can run your gas combi boiler at a lower flow temperature like 50°C to see if your house is warm enough at that flow temperature before you consider a heat pump. Your electricity bill will likely go up a little bit from the pump running more, but the gas bill might come down my more than that due to better condensing, depending on what temp it was before. <br><br>Check how many hours of the day it runs for. If it's on 24 hours then your radiators aren't big enough for that flow temp, or you need better insulation if you can't fit bigger rads. (insulation lowers energy consumption, but can actually decrease SCOP in the most efficient properties, if the heating power required is lower than the minimum output of the smallest available heat pump, then it has to cycle on and off intermittently which kills COP). If it's only running 50% of the time (on the coldest days of the year) then you can likely go even lower on flow temp, which your combi might not be able to do. <br> <br>If a room is too cold, you can upgrade a radiator. Spread the cost out, rather than one big "heat pump installation bill". My advice would generally be to fit the highest output radiator you can physically fit in a room. You can balance it back to reduce it's output if it's too powerful (unlikely). And the more capacity you have, the lower your flow temp can be, and the higher your SCOP. This also improves the efficiency of your gas boiler and saves you money regardless of if you get a heat pump! individual rad swap out can be a relatively easy DIY swap out if you fit the same length and can cost relatively little money.<br><br>If you're doing any work on the floor, put the insulation and pipe work for hydronic under floor heating in. It's way more expensive and disruptive to retrofit than the little extra to do it at the right time. and it's the best solution for a heat pump which we will all* eventually have.
7
@yp77738yp77739 · 5 months ago
That was interesting. The point made about checking the open energy monitor as a repository of installers happy to have the efficiency of their work in the public domain was important. That’s how I selected my installer, I filtered out any that weren’t or had SCOP of less than 4, I’m very happy with the outcome. On a like for like heat input vs gas, my heat pump on a TOU tariff and an optimiser, reduces my heating cost by 50%ish and it’s a better heat too. Those 10-15 really cold days are killers though, best not to look at the consumption or you will cry.
5
@FrankReif · 5 months ago (edited)
Buffer tank, volumizer, low loss header distinctions matter. You can replace rads with higher volume models to add more thermal inertia to avoid excessive cycling of the compressor. Or invest in an uninsulated simple cylinder as an additional lower temp emitter in an airing cupboard - they're substantially cheaper than low loss headers with hydraulic separation. <br><br>If you do a remodel of the attic, with good air sealing and modern thermal resistances, then heat loss of a property can drop by 30%. Retrofit of wall insulation another 20%. This could start causing issue with oversized heat pumps without volumizers.
3
@robdavis6317 · 5 months ago (edited)
Great video. For those considering a zero or minimal disrupt heat pump install with zero or minimal radiator changes, there is a cheap and easy way that you can find out exactly what life would be like after a heat pump install before actually committing to it. Spend a small amount of money on switching your gas boiler to running with WEATHER COMPENSATION, as used by all competent heat pump installations. This involves connecting an outdoor temperature sensor to the system / gas boiler and some minor changes in settings, which a competent gas engineer can do in a short visit. Avoid any micro-zoning by setting radiator TRVs to operate a few degrees above the intended room temperatures (e.g. TRVs set to 24C for 21C rooms) and set timer programmer thermostat controls so that the heating is on nearly all of the day at the required temperature, e.g. 21C with a small set back overnight, e.g. to 18C. Finally, read up on the weather compensation settings for your system and set the weather compensation curve so that the flow temperature is 55C when the outside temperature is -3C. (You can find appropriate graphs for the weather compensation curves in the manufacturers data / manuals). As convenient, try to keep most of the internal doors open, so that the whole house reaches an even and comfortable temperature. Now you have a system that will mirror exactly what would happen with a heat pump installed and a 55C set up. Run with this over autumn, winter, and spring, and see how well it works for you. If on the coldest days, the weather compensation curve corresponding to 55C flow temperature is working well and the house is warm, then try it with a lower curve for 50C or even 45C and see if that is still enough. Conversely, if the house is too cold, then move the weather compensation curve up, so that you get a 60C flow temperature at -3C. Experiment over a cold spell and tune in on the optimum setting for your house.<br><br>Properly set up, weather compensation works exceptionally well with gas boilers, resulting in radiator temperatures that are 30C to 45C at most much of the time, and very stable and comfortable room temperatures, without the overshoots that happen when the flow temperature is set too high, e.g. 60C or more when that is not needed given the outside temperature. As a bonus, the reduction in flow temperatures will mean that the gas boiler operates in condensing mode nearly all of the time, and will thus achieve close to its quoted efficiency, e.g. 90%+, saving money in the process.<br><br>Using weather compensation is this way will show very clearly what the effects of a heat pump install would be, and whether or not a zero disrupt install is really viable for your property. AI powered design tools making detailed heat loss estimates are great, but ultimately nothing can beat experiencing the practical reality of how low temperature heating actually works in your specific house. Further, if some rooms are a little cold on a given weather compensation curve, but the rest of the house is fine, then these are likely good candidates for radiator upgrades, providing a step-by-step pathway to getting the house "heat pump ready" or just achieving a more efficient and comfortable set up with your gas boiler.<br><br>If the results of weather compensation really don't work for you, then it's a matter of a few minutes work for a gas engineer to disconnect the weather compensation sensor and set the system to it's previous way of working. No harm, no foul, a heat pump just isn't for you, and you spent a relatively small amount of money finding out.<br><br>(In our case, with a now well insulated 1970s house, the 60C at -3C weather compensation curve on our Ideal Logic+ boiler (corresponding to Ideal's 18C room temperature set point) works just great. Hence we would most likely need a small number of radiator upgrades to get a 55C curve to work with a heat pump or more radiator upgrades to target a 45C set up).<br><br>[Added: Renewable heating hub video about weather compensation applies equally well to gas boiler installations].
1
@albireo-d1b · 5 months ago
My biggest issue is having a home based around 10mm plastic microbore to every radiator. Even Mitsubishi in their optimistic whitepaper, point to very limited power transfer for the radiator space I have. I'm seriously thinking of ASHP water tank with Electric boiler+ Tado smart radiator valves + radiator upgrades to utilise lower flow temperature, weather compensation and to provide a "minimum" disrupt approach. I think this would also provide a dynamic, responsive heating ability whilst having more control on electricity use( using timed cosy periods ). I fear being chained to 247 use and not allowing the home to drop more than 2 or 3 degrees, being on limited heating budget.
@nelsonoliveira1007 · 5 months ago
I installed an ATK 2 ton heatpump last June 2025. This past winter in Toronto in Jan and Feb we hit -30 Celsius and the heatpump worked like a charm. I never used the 2 stage Bryant furnace. Very impressed so far.
1
@hogwash1462 · 5 months ago
I really did want to move to a heat pump solution but it seems like fledgling car industry when the scarce customer had to understand the technology to ensure they avoid the pitfalls and could run the thing. I've had quotes with no breakdown and no design, recommendations to re-pipe the house entirely with 22mm (from 15mm) and proposals for underfloor heating on an uninsulated suspended floor. Some crazy pricing too which are then partially offset by the grant. I'm rapidly coming to the conclusion that I should just replace my ancient boiler with a new one at one third of the cost and almost zero risk and use low rate electricity overnight to heat my water. Maybe the industry will improve in the next 5-10 years?
@leslieburrows5293 · 5 months ago
Mars Simon what a great video you have put together here very informative in most areas of the topic especially for people thinking about installing a heat pump.<br><br>One thing that still I find confusing is when you talk about buffer tanks I would like to see a video with diagrams or pictures of the differences between 2/3 or 4 pipe set ups I have had a Daikin pump now for just shy of 2years and love the thing the home as never been as comfortable because of the constant temperatures and I have watched I think all of your videos on this channel and learned a hell of a lot but as I said above a picture or diagram can speak a thousand words an make things much easier to understand <br>So there ends my comment and thank you Mars and Simon for your excellent video please give us more thank you.<br>Les
@JOOI525 · 5 months ago
Wish Simon would just say what he thinks! 😅...... A great discussion Mars.
3
@keithgeorge7338 · 3 months ago
Is the temperature in each room controlled by the valve in the radiator? So, when my wife has her hot flush, I have to turn the valve down in the room we are in and open the window and turn down the bedroom valve? Just trying to understand how it works practically? The system just keeps my conservatory at comfortable temperature all night? How do you operate heating all the time at that change over periods in spring and autumn when only occasional heat in certain rooms is needed with changes in sun heating? Cheers.
@MaccGaz · 4 months ago
My zero disrupt option was good that it wasn't changing too much, but with the Heat Geek app, it just didn't seem to be possible to tell it "how much is it for this heat pump and radiator changes of these sizes and let me know the cost and efficiency guarantee". The numbers had to be messed around with to get the system to do what we wanted and even then we couldn't actually get there in the end. It was also confusing why the Pro @7kw was ok but the Plus @5kw had to be used, despite about a 5.8 heat loss.<br><br>I feel like the system is too restrictive and there does seem to be a baked in cost on top. What's the point of changing less, if it still costs the same amount as changing more?
1
@robdavis6317 · 5 months ago
ASHP installations are still far too expensive. I've had quotes from two of the industry leaders for zero and minimal disruption heat pump installations, which were within £200 of each other at just over £12000 not including the £7500 BUS grant. These assumed no changes to the existing hot water cylinder, or pipework, and recommended 1 radiator change. Also, the heat pump would be located close to where the gas boiler is now, so minimal additional pipework needed there. Both quotes were for the same 10kW ASHP. Subtracting the heat pump purchase price and radiator change leaves £6000 for installation costs. <br><br>In last few years, I have had a new gas boiler fitted for £3000 in total including installation costs of £2000. Further, I have had two air-to-air heat pumps fitted for £3200 in total including installation costs of £1600. What I cannot understand is how installation costs of £6000 for a single ASHP can be justified, i.e. £2400 more that the combined installation costs of a gas boiler (£2000) and two air-to-air heat pumps (£1600). (For reference, the gas boiler work needed gas certification, extra pipework to move the boiler to a different location, a hole drilling in the wall for the flu etc. The air-to-air heat pump work needed F-gas certification, electrical hook up, mounting indoor and outdoor units , running refrigerant pipework etc.). <br><br>Am I missing something important or are ASHP installation prices a rip off because so much of the cost is covered by the BUS grant?
2
Up next

What’s Worrying Heat Pump Owners? Graham Hendra Explains
Renewable Heating Hub · 12K views

Why Stiebel Eltron Does Heat Pumps Differently in the UK
Renewable Heating Hub · 511 views

This Budget Heat Pump Could Finish Boilers (Glow-worm Review)
Heatable · 62K views

Out With The Old, In With The New! Robert's Heat Pump Install!
Everything Electric TECH · 133K views

Heat Pumps in Old Houses: What Actually Matters? (From Our Real Data)
Furbnow · 27K views

This El Niño Could Permanently Change Our World
New Scientist and Dr Russell Arnott · 982K views

This Insulation Secret Will BLOW YOUR MIND
Heat Geek · 271K views

Are Mini Split Air Conditioners Worth It In The UK? 5 Pros and Cons
Electrum Electrical · 96K views

Why Does Every New Heat Pump Come with an Unreadable & Useless Controller?
Renewable Heating Hub · 4.2K views

Is Your Home Energy System Becoming an Expensive Frankenstein?
Renewable Heating Hub · 5.1K views

This Beats Every Heat Pump in Britain.
Urban Plumbers · 131K views

Did Your Installer Actually Commission Your Heat Pump Properly?
Renewable Heating Hub · 1.9K views

What’s the Best Way to Use a Heat Pump & Mistakes You Must Avoid?
Renewable Heating Hub · 12K views

18 Months Later: Would I Still Buy A Heat Pump?
Jonathan Tracey · 25K views

Heat Pump Coming! Big News, Very Sad News, a Grumpy Wife, and Coffee (Obviously)
Andrew Till / Mr. EV · 85K views

Could Cheap Heat Pumps Become Britain’s Next Home Heating Scandal?
Renewable Heating Hub · 3K views

The Janitor made Him HUMBLE | Anatoly Gym Prank
ANATOLY · 370K views

What Temperature Should Hot Water Be? | LEGIONELLA Explained
Heat Geek · 125K views

Is Britain’s Heat Pump Problem Actually An Installer Problem?
Renewable Heating Hub · 3K views

Why Are So Many Heat Pumps Failing Homeowners?
Renewable Heating Hub · 9K views