Ads skipped

Spacer Installation on 765,000 volt line

14M views · Feb 21, 2013 · Travel & Events

Comments · 6.4K

  • @PBandJsandwich · 7 years ago

    I'm amazed that a helicopter can lift a man with balls that big.

    4.1K

  • @n6mz · 6 years ago

    That helicopter pilot is BEYOND INCREDIBLE. What a team.

    3.9K

  • @dolphinchair7491 · 5 years ago

    Shoutout to the people who put their lives on the line so that we can keep watching YouTube

    6.2K

  • @enilenis · 3 years ago (edited)

    For those wondering how it works - the long metal rod that shoots out lightning bolts is a magic wand, and both men in the video are wizards. There can be no other explanation.

    643

  • @uzaiyaro · 7 years ago (edited)

    Seems to be a lot of folks who might not know exactly how these guys aren’t burnt to a crisp. There’s a few things going on here that are critical to doing this job safely. And as you might have guessed, the zappy stick plays a huge part. Basically what they’re doing, is charging themselves to the same potential as the high tension lines. If this sounds positively insane (pardon the pun), you need to remember that electricity only fries you when it has somewhere to go, because exactly like water flowing from high to low pressure, electricity flows from high to low voltage. It wants to find the easiest path to ground (or neutral, so going back to where it came from), which is not being provided. Water wants to find the easiest way to a lower pressure, it&apos;s the same thing. This is so much the case that the Chinese sometimes call voltage electrical pressure.<br><br>Incidentally, this is also how the safety circuit breakers (RCD or RCBO) work. When everything is happy, the amount of power coming in on the live pin is identical to the amount going back out on the neutral pin, thus completing the circuit, all the way from the generator at the power station, to you and your appliance through live, and all the way back to the generator, on neutral. The RCD monitors these, and it is looking at the current going to ground. Many devices have a little bit of leakage to ground, and its not really an issue. Your RCD will tolerate a certain amount of ground leakage, typically 30mA, but above this, it will trip. So if it detects a large amount of imbalance or conduction to ground, then it trips. This could be, for example, you drop a hair dryer in a bathtub. That hair dryer has a ground pin on it. The ground pin in any device <b>will only conduct in the case of a fault.</b> If something blows up, ideally that energy will be conducted to ground and dissipated. Your RCD will detect this and trip in a matter of milliseconds, which could save your life.<br><br>Think about lightning striking a tall building. It does this because that building has a lightning conductor running through it, to earth. The engineers deliberately design the building so that it attracts lightning to this specific conductor, and not somewhere else that can cause major damage. If you&apos;ve ever wondered what those very thin wires atop these power lines are, they are called static lines. They provide a direct path to ground so lightning prefers these, instead of the HT wires.<br><br>Because there is physically nowhere else for the electricity to go, there’s no potential difference, so there’s no problem. The electricity just harmlessly flows around them. The zappy stick is a safe way to bring yourselves up to the same potential in a controlled way. Once contact is made, the clamp is applied to the line to make sure connection is not lost. There’s two paths for electricity to flow, and neither of them are to ground. Basically it’s a really, really cool faraday cage without the cage.<br><br>Also, those four conductors are carrying the same phase, so there’s no problem here, either. The other phases are on the other lines on that pole, so essentially, all four conductors he’s dealing with here, are carrying the exact same thing. So, again, there’s nowhere for the electricity to go. The braces are metal with a rubber gasket, and that gasket is purely there to stop chafing. It&apos;s like having two wires connecting from one place to another place. Even though they are touching, they are carrying the exact same thing, so nothing happens. What <b>will</b> happen, is that those two wires will share the load, so this is actually a good thing in many cases. No short circuit can happen here because there&apos;s no difference in potential; same voltage, same phase, same circuit, same everything.<br><br>By far the most dangerous thing here, is the helicopter being so close to the lines. A tiny gust of wind, will send it crashing into the lines, and those guys to their deaths.<br><br>Hope this clears a few things up. I&apos;m not a sparky yet, but I am interested in learning for a potential career. Maybe. If I got anything wrong, please do kindly correct me!<br><br>Edit: I have since learned that the neutral doesn’t go all the way back to the power station. Which would explain why a single three phase high voltage circuit has three wires, not four. The neutral is more or less a product of the transformer serving either you, or your neighbourhood.

    7.4K

  • @keaganbarnes2856 · 7 years ago

    Now this is something I wouldn’t mind paying for with my taxes

    3.7K

  • @Loehlenco · 7 years ago

    And his GoPro came back fully charged.

    6.5K

  • @PERTEKofficial · 4 years ago

    Am an electrician but I couldn’t imagine sticking a wand out and watching an arc like that get drawn, and then go “yup, time to work on this”. Huge respect for this line of work.

    891

  • @N0stalgicLeaf · 7 years ago

    Incredible. These invisible people keep our lights on 24x7. It&apos;s sweat, ingenuity and indomitable spirit. Nothing but respect for these highly skilled laborers.

    2.1K

  • @carloscabrera8510 · 7 years ago

    I&apos;m more impressed by the helicopter pilot. DO YOU KNOW HOW GOOD YOU HAVE TO BE TO HOVER THAT CLOSE TO POWER LINES. DAMNNNNNN

    3.8K

  • @m.a.6020 · 5 years ago

    Mad respect to the guy doing this, and also to the pilot getting extremely close to something which would easily be able to kill them both if he fucked up

    2K

  • @kevinberniebarron7548 · 2 years ago

    My Dad worked for the old Kansas City Power and Light (K.C.P&amp;L.) for 36 years. (He&apos;s been gone for 22 years), but he worked as a Lead lineman splicer. He did not work from &nbsp;a helicopter, but worked on extremely high voltage lines! <br>In my opinion, he was one of those &nbsp;&quot;invisible&quot; heroes!<br>Nothing but total respect!<br>God bless all of them!

    76

Up next

LIVE

Cart Launch and spacer changeout

DuckMugger · 4.7M views

LIVE

Lineman at work/ how to ride a Bike on Transmission Line/ broken line

lineman at work · 571K views

LIVE

Jaw-Dropping Demolitions Compilation That Will BLOW YOUR MIND! #14

Forestry Tech · 486K views

LIVE

Flight on the Antonov An-2 biplane: from engine start to landing - Legendary Sound

Sergey Vyatkin | An-2 pilot · 5.1M views

LIVE

INSANE OLD DIESEL LOCOMOTIVE Cold Starts Exploding Smoke & Thunder!

Cars and Engines · 285K views

LIVE

WLKY Skycrane Erickson Antenna Lift

Brad Warren · 13M views

LIVE

Smart Workers | Working with Talented Engineers #23 #tips #construction #workers

Build Brains · 1.1M views

LIVE

Firing the Lorentz Plasma Cannon

LightningOnDemand · 7.5M views

LIVE

Ship Launch | Awesome Waves, Fails and Close Calls

#Mind Warehouse · 128K views

LIVE

KDLT-TV 1999ft tower being climbed

Engineering · 29M views

LIVE

WKBD New Antenna up

TowerandTurbine · 2.1M views

LIVE

How we change voltage on a transformer

Bobsdecline - Lineman blogger · 1M views

LIVE

African Airplane Compilation | African Aviation

Bad Goy · 11M views

LIVE

25 Minutes of Incredible Demolition Videos

Underworld · 6.2M views

LIVE

Partial dismantling of an 80-meter crane boom

schrauberfaust · 640K views

LIVE

Jaw-Dropping Bulldozer Operator Skills So Crazy You’d Think They’re Fake! #2

Green Tech · 3.8M views

LIVE

Guy's day on the power lines service crew! | Guy Martin

Guy Martin · 155K views

LIVE

Insulator Changeout On H-Structure NLC

David Wilkins · 6.3M views

LIVE

When Electricity Went Out of Control

UNSORTED · 1.1M views

LIVE

Inside the World’s Craziest Job: Aerial Power Line Work!

BuildWitt · 787K views

LIVE

What Happens to Earth If Humans Disappear Tomorrow?

The Last Day · 384K views

LIVE

Life of a TOWER CRANE Operator!🏗️ (POV My Morning Climb)

SkyBox Operator · 253K views

LIVE

Most Ridiculous Worker Mistakes Caught on Camera

#Mind Warehouse · 773K views

LIVE

Pilot Uses Reverse Thrust Too Early

lucaas · 1.7M views

LIVE

Wenn die Elektrizität außer Kontrolle gerät

#Mentale Zuflucht · 226K views

LIVE

How Dangerous Is Nitroglycerin Really?

Grandpa Walter · 278K views

YouTube, with the door locked.

Aegis plays a clean stream instead of YouTube's player, so pre-roll ads, trackers, and fingerprinting never ride along. Drop Shields any time if you want the official player back.