Daikin VRV 6 / My First Time Connecting the Type 4 Checker to a Daikin VRV R
6.1K views · Sep 27, 2024 · People & Blogs
Comments · 22
@damowdotnet · 2 years ago
“Not really sure what to do about that” - yeeuuup 😞
3
@AlexYT_news · 2 years ago
Thank a lot for video. Very interesting 👍
1
@michaelburns5680 · 2 years ago
You can put it in charge mode (mode 20 and shut the liquid line service valve) <br>and charge it down the liquid line straight from the bottle. So no chance of any liquid getting back and much faster if you’re chucking in a lot of charge.<br><br>Also if you put it through test mode before chucking in the additional charge it may judge the line lengths wrong and get its target pressures wrong. Charge mode lets you fire it up before test mode too.
@nategadow4482 · 1 year ago
What brand adapters are you using?
@heftyeh · 2 years ago
Do you have a lot of sites with BS boxes mounted outside? I have never seen them outside being in Canada. As always great video!
2
@JesseDoesHVAC · 2 years ago
Condenser is very quiet im actually impressed (yes i know its technically not at 100%)<br><br>Personally dont rate Daikin, fix/replace way more of them than i install 😂<br><br>Fellow Melbournian hvacr tech 🤘
@VoiD1x · 11 months ago
You can’t use BTSC with a laptop can ya?
@NewDestinationEng · 2 years ago
I guess all VRV6 are heat recovery actually <br><br>That new service valve design is bad and will eventually leak. Why wouldn't they keep the traditional one with a cap?!
1
@daniellonergan5669 · 2 years ago (edited)
Daikin come with little plastic caps that sit over the shut off valves......horrific idea 😂
@mark111943 · 2 years ago
As a customer I would want you warranty it otherwise it will cost me money in the future! Maybe when you add the other heads.<br>Thanks for all your informative vids.
1
Up next

Daikin VRV II / Heat Recovery System Has Performance Issues
HVACR AUS · 4.2K views

HVRF 5201 Fault: Leak in a Fire-Sealed Riser Meant Running 14 Floors of New Pipe
HVACR AUS · 2.5K views

Temperzone / More Issues With This 55kW Package Unit
HVACR AUS · 3.6K views

Introduction to VRV/F Systems with Roman Baugh
HVAC School · 154K views

How Economizers Cool Buildings Without Running the Compressor
Hvac Tom · 1.4K views

Blank PAR-41 Screen? Check This Before Replacing the Controller
HVACR AUS · 2.9K views

On-Call For Back-to-Back 38 Degree Days
HVACR AUS · 2.9K views

Daikin D-Checker | Connecting & Setup | D-Checker Ep.2 (1-29-2021)
Inverter Always · 20K views

Mitsubishi AE-C400 Stuck on Startup. Fixing a Controller That Won't Initialise
HVACR AUS · 1.7K views

A Few Jobs From Multiple Sites: Ep 6
HVACR AUS · 2.7K views

Mitsubishi Electric / City Multi VRF 7102 Fault
HVACR AUS · 8.3K views

The Basics of Service Checker
Roman Baugh - VRF Tech · 3.9K views

How to test Daikin PCB for Communication Faults.
Mitch Attwood · 21K views

Learn VRF air conditioner Dip Switch Setting | Panasonic FSV-EX | Installation Instruction
Bon Mj · 4K views

Service Checker Data Analysis - Low Ambient Heating Issues
Roman Baugh - VRF Tech · 3.4K views

Trane RTAC Pt. 2 - Filter Drier, Vacuum, Recharge
DFW HVAC · 17K views

ACS GAS TRAINING / CONTROLS | NGCFE
Allen Hart · 48K views

Plumbers Videos - Heat Interface Unit - HIU - How Do They Work HIU I20 i30N
Allen Hart · 31K views

Daikin / High-wall Split System Won’t Turn On
HVACR AUS · 5.7K views