Powering a Light With a Fence Post & Scrap Wire - SWER (Single Wire Earth Return) Demonstration
670K views · Nov 20, 2021 · Education
Comments · 1.3K
@alec4672 · 4 years ago (edited)
When I was 14 we built a cabin about a mile and a half into the woods behind my parents house. After lots of Google searches we ended up grabbing two microwaves and used one transformer to boost the voltage and one to step it back down. We kept the transformers in 5 gallon buckets of mineral oil to keep them cool. With a quite a bit of patched together Romex in the trees on electric fence insulators we ran the hot through the trees and took care of the neutral with ground path return. It worked well but it terrifies me to think about now 😂
350
@MarkDenovich · 4 years ago
We used to use this principle to collect earthworms for fishing. Basically a ground rod (usually scrap steel) connected to hot, with an insulated handle. Stick it in the ground and any worms in within a few feet of the rod would be driven to the surface. If you were on your hands and knees to pick up the worms you’d feel the tingle, especially if the grass was wet.
69
@davidhenderson3400 · 4 years ago
Fun Fact. Back in the early days in San Francisco electric trolleys were powered this way. After a few years water line started to leak all over the place. Turns out the electric return was eating the water pipes. They got thinner and thinner until they could no longer handle the water pressure.
172
@AKULA689 · 5 years ago (edited)
That's how my electric fence works, I use a bucket of salt water poured at my ground post!
19
@jimlongley9531 · 4 years ago
My own experience with SWER is as a telephone technician. The farmer's daughter had moved home to live with her elderly parents, her father was suffering from the early stages of Alzheimer's. She called in to complain about frequent noise on the telephone line. Her mother told her it was okay, all she needed to do was turn the barn lights off. When a tech went out there to check it, he tested the line and everything looked ok except for an imbalance in the capacitance of the line. As he started to trouble shoot the system he received what could have been a life threatening shock.<br><br>At some time in the past, the someone (the father?) had decided to control the lights in the barn using one side of a telephone drop wire and SWER, to trigger a relay in the barn to turn the lights on. The way it had been set up, the wire to the relay, which was also the drop wire to the extension bell in the barn, stayed energized but open without the relay contactor energized, putting 120V potential resting on the drop. Because of the locking style of relay, when the lights were on some of the energy was tapped to hold the relay closed, which also put voltage on the return path for the bell and noised up the associated phone line.<br><br>My own involvement was as a technical support engineer, called in because of a dispute with the customer. It seems that after the telephone was repaired, they no longer could turn the barn lights on and off from the button in the kitchen.
187
@billybob8686 · 4 years ago
Depending on your orientation when near a swer system, if your legs feel heavy, your legs are conducting electricity up one leg and down the other.But you don't feel like your getting a electric shock. Lifting one leg breaks that circuit, then hop away from the metal rod. There is a meter to scan the ground, ( like a metal detector ) . So if you see dead cows/sheep around a swer system, they might have been electrocuted, do not approach the area.That swer system is still in use here in Victoria Australia for farm houses.
164
@douglaswindsor120 · 4 years ago
About 55 years I went with my brother in-law to look at an old generator in an old service station garage it was massive it supplied the whole town and farm out ten miles away running power out by the old barbwire fencing the old gentle man who showed us this massive single piston motor told how the owner of the plant would leave work at the service station at 900 leaving the generator running unattended overnight if the generator was overloaded it would power out and die and the owner didn't get out of bed to restart it so no power until he got to work at eight in the morning since you could hear it from every where it serviced if they heard it laboring every body rushed to shut down all power they could otherwise no power till morning so pumps and anything else would be turned off until the generator was running properly again that's something people wouldn't put up with and safety regulations wouldn't allow now can you imagine the noise and the danger of those barbwire fencing power run through them back then people were grateful just to have the convenience of having power you could have hot and cold running water a toilet tub and sink a coal Stoker for the furnace get up to a nice warm house convenience those in big cities took for granted
27
@strayblackcatsmeow · 4 years ago
That is actually very dangerous at utility voltages and currents. An earth return goes to the generator source, not transformer or panel. You are tied into a utility, return is to their generator. All houses on the service are part of the circuit. It's important to understand that current paths through earth are unpredictable. If your neighbors house is closer than your panel, their panel ground will become part of your return path. If they have an unbonded pool between your two panels or unbonded plumbing in thier home, you can potentially kill them. Any underground metal pipes can also become a current path allowing current travel further than direct line. Further, stray currents will negatively effect dairy cows even at low levels if any are in the area. If you want to study safe earth returns, study the works of Nicola Teslas high frequency generators.
167
@jackmcclure2264 · 4 years ago
Several years ago I was asked by my brother in law to help diagnose a leak problem. His waterline to the dishwasher leaked water onto kitchen floor. I was testing in basement and was getting electrical readings on the incoming waterline from the well. Long story short was the sheep barn by the well had a bad connection on the overhead neutral line. When he ran an electrical heater in the sheep barn, the current was following the water line back to the house and through the stainless braided water line to the dishwasher, which was grounded. It created an arcing that melted the line. I recalled that I was getting 86 volts coming in on the water pipes. Weirdest thing I have ever encountered.
38
@joesmith4222 · 4 years ago
This one works too. Insulate an 85 ft. bare copper wire a foot off the ground on both ends. Tap a third of the way down with a coaxial cable, attach the coax to one side of the bulb and the other side to a ground wire. Gets you 15 watts by day and 8 watts by night. It works off of solar radiation. Try it.👍
20
@curtwuollet2912 · 4 years ago
Yes, it works. Heavily frowned upon by inspectors and power companies.
26
@fillg · 4 years ago (edited)
My grandfather had a similar setup to power the electric fence wire around his pig pen. He took a single wire from his shed to a light bulb then ran a bare wire from there around the pig pen on fence insulators so there was no path to ground, but when a pig would try to get out, it would touch the wire while standing on the ground and that would complete the circuit. Pig got shocked, squealed, stayed in the pen. The purpose of the light bulb was so that if some grass grew up and leaned on the fence or something else was on the wire, the light bulb would be lit and he would know the fence needed attention. A side benefit was that the electric fence used no power whatsoever unless it was shocking something or needed attention.
43
Up next

EP 51 - Power Through Dirt: Single-Wire Earth Return @ 120V
Dielectric Videos · 121K views

Solar Is Much Simpler Than You Think! | Off-Grid Solar Explained
Smarter Sparky · 1.4M views

The Rise and Fall of Bessemer Steel — The Blast of Air That Rolled Carnegie's Rails
Grain & Temper · 18 views

How Solid Copper Cuts Through Tank Armor Like Water
VEIN Material · 1.4M views

Stealing Energy From Radio towers Using Plasma (ft. Geerling Engineering)
Plasma Channel · 2.2M views

Will 120v To Ground Trip a Circuit Breaker?
Benjamin Sahlstrom · 254K views

Power saver plugs just got a bit darker
bigclivedotcom · 996K views

You'll Finally Understand How a Generator Can Kill a Lineman
The Grid Teacher · 513 views

We Can Have This COLOSSAL Dragline for FREE - If We Can Get It Running And Walking!!!
Randy's Relics · 1.7M views

You'll Finally Understand Why Your Pole Has Only 2 Wires
Kilowatt Nation · 12K views

An Old Microwave And What To Do With It - An Electromagnet And A Phone Charger
Robert Murray-Smith · 734K views

How To Get 220V/240V From Two 120V Outlets. No Electrical Panel Work Required...
RWGresearch · 591K views

Why Neutrals and Grounds are Separated in a Sub Panel
Benjamin Sahlstrom · 3.7M views

What Happened to Litz Wire? The Strange Wire That Made Radio Coils More Efficient
Fallen America FM · 51K views

You'll Finally Understand Why Power Lines Have Three Wires
Kilowatt Nation · 266K views

Sand Battery heater. Create free heat of 500F using solar electricity! Texas Prepper Projects
Texas Prepper Projects · 642K views

Storing Solar Power on my ROOF!!!
Quint BUILDs · 5M views

Reviving Dead Batteries With A Stick Welder
Uncle Tony's Garage · 1.8M views

When Did the Soviet Generals Realize They Had Lost the Cold War to America?
AWM Cold War and 2 more · 159K views

How To Chainsaw Like a Boss. This Could Save Your Life.
FarmCraft101 · 9M views