The Worst Fault Finding Video You Will Ever See - UK Electrics
40K views · Oct 9, 2024 · Entertainment
Comments · 91
@OCD_Sparkies · 1 year ago
You ought to send that dodgy old part off to Big Clive for a teardown to see why the fault occurred
5
@Richardincancale · 1 year ago (edited)
Don't chuck it in the skip - give it to David Savery for him to take apart and figure what was wrong with it!
35
@williammartinculleton5875 · 1 year ago
As a “ young man “ of 86 , I’ve installed those voltage operated yokes many’s the time, never liked them then. All the rage in Co.Wexford back “ in the day” 😂😂😂 Every day is a school day 👍
3
@garygoode7479 · 1 year ago
Old VO ELCB should have been wired with separate earths, one with reference to the stake, and the other to the installation. Looks like on the video that these are connected together in the earth block. It would not trip. The voltage may have been from the internal coil, when the test button is operated, mains voltage is applied to one side of the coil, back to earth. If faulty/stuck test button then voltage at main earth terminal.<br>Good job you didn't start removing the cpc's from earth terminal.😮
14
@freelifeproductions · 1 year ago
i can feel your pain man.. after a night like that.. horrible... at least you fixed it.. lucky he's getting a rewire done.. thing is a mess
10
@alvina69 · 1 year ago
When you said “You’re not gonna like it” I thought you were going to get the Kopex out the van 😂😂😂
3
@jamesmee6696 · 1 year ago
The old voltage operated ELCB, can put a voltage on to the earthing conductor usually 50to120 volts that’s why they should be removed when you come across then ! 👍🏾
7
@oddjobbill · 1 year ago
Well done mate for not giving up 👍👍👍
6
@ColinDH12345 · 1 year ago
It would have been interesting to break the old DP switch open to see what may have broken down. Was OK in the past so what changed? Great video. I was there with you trying to help 🙂
4
@the_industrious_electrician · 1 year ago
Great video! I was scratching my head with that fault, did not realise you hadn't changed the voltage breaker. lol. Tiredness is a killer. Well done, I have a proper love hate relationship with fault finding, can be so frustrating but the relief of finding the problem is worth it.
11
@KimMason-qq7hk · 1 year ago
Hi nick the dreaded early hours change over every sparkies nightmare
3
@mitchmix999 · 1 year ago
Good fault finding skills. There's an art to fault finding in all trades. Experience plays a big part in it.
2
Up next

Over TheTop Electrics? - You Be The Judge
N Bundy Electrical · 33K views

The Worst JOB I Have EVER BEEN TO - Electrician
N Bundy Electrical · 203K views

When Safe Isolation Isn't Enough - Deadly Diverted Neutral Current
eFIXX · 94K views

CAN WE SAVE THIS ABANDONED 6X6 RECOVERY TRUCK?
Mr Hewes · 754K views

Fault finding on a continuity tester for am2 ⚡️
Elex-electrical · 8.4K views

Intermittent Tripping: These Faults Are The Hardest To Finds
Eastway Electrical · 38K views

Most Electricians Won't Do This
N Bundy Electrical · 41K views

I Have Strong Feelings About Air Conditioning in the Tech House
Linus Tech Tips · 746K views

Trump just unveiled a plan to avoid admitting ‘we screwed up’ | Scott Lucas
The Trump Report and Scott Lucas Worldview · 183K views

Domestic Consumer Units 2024 - Overview, RCBOs, MCBs, AFDDs, Surge Protection
John Ward (jwflame) · 88K views

My Consumer Unit Secrets 🤫 How to Install a Consumer Unit/Fuse Box in 2026
Artisan Electrics · 180K views

Giant RATS VS UK Cables - Electrical Faults Everywhere!
N Bundy Electrical · 19K views

Nearly KILLED by a CRAZY fault! What on earth is going on? 💀
Artisan Electrics · 1.1M views

The End Result Of The Rewire
N Bundy Electrical · 22K views

Electrician Told us to F**K OFF!
N Bundy Electrical · 137K views

Copart MG EV £1,850 Salvage - Brick or Result - £0 fix?
71six · 157K views

Epic Low Cost Consumer Unit - To Fix Deadly Consumer Unit🤠
Mike Builds - GHC · 232K views

Adding a plug socket? Don’t get it WRONG!
Leon Rygol and Rygol Electrical and Renewable’s (Bristol) · 487K views

Working in a 2000A widow maker
Residual Electrical · 363K views

Under Ground Solo Rewire - UK Electrics
N Bundy Electrical · 20K views