Ads skipped

The Worst Fault Finding Video You Will Ever See - UK Electrics

40K views · Oct 9, 2024 · Entertainment

Comments · 91

  • @OCD_Sparkies · 1 year ago

    You ought to send that dodgy old part off to Big Clive for a teardown to see why the fault occurred

    5

  • @Richardincancale · 1 year ago (edited)

    Don't chuck it in the skip - give it to David Savery for him to take apart and figure what was wrong with it!

    35

  • @williammartinculleton5875 · 1 year ago

    As a “ young man “ of 86 , I’ve installed those voltage operated yokes many’s the time, never liked them then. All the rage in Co.Wexford back “ in the day” 😂😂😂 Every day is a school day 👍

    3

  • @garygoode7479 · 1 year ago

    Old VO ELCB should have been wired with separate earths, one with reference to the stake, and the other to the installation. Looks like on the video that these are connected together in the earth block. It would not trip. The voltage may have been from the internal coil, when the test button is operated, mains voltage is applied to one side of the coil, back to earth. If faulty/stuck test button then voltage at main earth terminal.<br>Good job you didn&apos;t start removing the cpc&apos;s from earth terminal.😮

    14

  • @freelifeproductions · 1 year ago

    i can feel your pain man.. after a night like that.. horrible... at least you fixed it.. lucky he&apos;s getting a rewire done.. thing is a mess

    10

  • @alvina69 · 1 year ago

    When you said “You’re not gonna like it” I thought you were going to get the Kopex out the van 😂😂😂

    3

  • @jamesmee6696 · 1 year ago

    The old voltage operated ELCB, can put a voltage on to the earthing conductor usually 50to120 volts that’s why they should be removed when you come across then ! 👍🏾

    7

  • @oddjobbill · 1 year ago

    Well done mate for not giving up 👍👍👍

    6

  • @ColinDH12345 · 1 year ago

    It would have been interesting to break the old DP switch open to see what may have broken down. Was OK in the past so what changed? Great video. I was there with you trying to help 🙂

    4

  • @the_industrious_electrician · 1 year ago

    Great video! I was scratching my head with that fault, did not realise you hadn&apos;t changed the voltage breaker. lol. Tiredness is a killer. Well done, I have a proper love hate relationship with fault finding, can be so frustrating but the relief of finding the problem is worth it.

    11

  • @KimMason-qq7hk · 1 year ago

    Hi nick the dreaded early hours change over every sparkies nightmare

    3

  • @mitchmix999 · 1 year ago

    Good fault finding skills. There&apos;s an art to fault finding in all trades. Experience plays a big part in it.

    2

Up next

LIVE

Over TheTop Electrics? - You Be The Judge

N Bundy Electrical · 33K views

LIVE

The Worst JOB I Have EVER BEEN TO - Electrician

N Bundy Electrical · 203K views

LIVE

When Safe Isolation Isn't Enough - Deadly Diverted Neutral Current

eFIXX · 94K views

LIVE

CAN WE SAVE THIS ABANDONED 6X6 RECOVERY TRUCK?

Mr Hewes · 754K views

LIVE

Fault finding on a continuity tester for am2 ⚡️

Elex-electrical · 8.4K views

LIVE

Intermittent Tripping: These Faults Are The Hardest To Finds

Eastway Electrical · 38K views

LIVE

Most Electricians Won't Do This

N Bundy Electrical · 41K views

LIVE

I Have Strong Feelings About Air Conditioning in the Tech House

Linus Tech Tips · 746K views

LIVE

Trump just unveiled a plan to avoid admitting ‘we screwed up’ | Scott Lucas

The Trump Report and Scott Lucas Worldview · 183K views

LIVE

Domestic Consumer Units 2024 - Overview, RCBOs, MCBs, AFDDs, Surge Protection

John Ward (jwflame) · 88K views

LIVE

My Consumer Unit Secrets 🤫 How to Install a Consumer Unit/Fuse Box in 2026

Artisan Electrics · 180K views

LIVE

Giant RATS VS UK Cables - Electrical Faults Everywhere!

N Bundy Electrical · 19K views

LIVE

Nearly KILLED by a CRAZY fault! What on earth is going on? 💀

Artisan Electrics · 1.1M views

LIVE

The End Result Of The Rewire

N Bundy Electrical · 22K views

LIVE

Electrician Told us to F**K OFF!

N Bundy Electrical · 137K views

LIVE

Copart MG EV £1,850 Salvage - Brick or Result - £0 fix?

71six · 157K views

LIVE

Epic Low Cost Consumer Unit - To Fix Deadly Consumer Unit🤠

Mike Builds - GHC · 232K views

LIVE

Adding a plug socket? Don’t get it WRONG!

Leon Rygol and Rygol Electrical and Renewable’s (Bristol) · 487K views

LIVE

Working in a 2000A widow maker

Residual Electrical · 363K views

LIVE

Under Ground Solo Rewire - UK Electrics

N Bundy Electrical · 20K views

YouTube, with the door locked.

Aegis plays a clean stream instead of YouTube's player, so pre-roll ads, trackers, and fingerprinting never ride along. Drop Shields any time if you want the official player back.