  • @acservicetechchannel · 6 years ago (edited) · pinned

    Explore More From AC Service Tech Here! <br>▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬ <br>HVAC/R Online Training Courses: <a href="https://www.acservicetech.com/academy">https://www.acservicetech.com/academy </a><br>▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬ <br>Learn More About Mini Split Systems With our Mini Split Training Book &amp; Workbook: <a href="https://www.acservicetech.com/mini-split-book">https://www.acservicetech.com/mini-split-book</a> <br>▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬ <br>2nd Edition Refrigerant Charging Book &amp; Training Resources: <a href="https://www.acservicetech.com/newacbook">https://www.acservicetech.com/newacbook </a><br>▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬ <br>Take our Free Online Training Resources: <a href="https://www.acservicetech.com/resources">https://www.acservicetech.com/resources </a><br>Our HVAC Tool List: <a href="https://www.acservicetech.com/tools">https://www.acservicetech.com/tools </a><br>Our Free HVAC Quizzes: <a href="https://www.acservicetech.com/quizzes">https://www.acservicetech.com/quizzes</a> <br>Our Free HVAC Training Articles &amp; Quick Tips: <a href="https://www.acservicetech.com/articles">https://www.acservicetech.com/articles</a>

    19

  • @davidb2438 · 5 years ago

    I have bought all your materials and probably watched 200 hours of your videos. &nbsp;I’m retired and went and got my EPA 608 certification also. &nbsp;I’ve done 4 installs and helped getting ACs running again for friends and family thanks to you. &nbsp;I love videos like this one which helped me diagnose a problem for a friend. I think you have the best instructional videos of any trade on YouTube. &nbsp;Thanks, Craig!

    187

  • @Howie875 · 6 years ago

    Sometimes a restricted strainer or filter drier will either sweat or freeze up and you can visually see this. This is caused because the restriction will actually induce a pressure loss in the refrigerant which causes it to begin to evaporate,

    15

  • @coldfinger459sub0 · 6 years ago

    That gave me flash Back to 12 years old my dad showed and explained that to me exactly like that to. Every kid should learn a trade years before they enter high school

    27

  • @michaelrodgers1545 · 5 years ago

    On rooftops check your economizer to make sure it’s functional. I had all the symptoms of a txv; tested with warm water. Ended up replacing it because it seemed bad. Turned out the economizer wasn’t functioning and the return air was getting too cold and with that bulb on the top part of the coil on the suction line it was getting frosty causing the suction pressure and saturation temp to go down. As soon as I manually cracked the economizer, it solved the issue.

    6

  • @proanswers · 6 years ago

    So the txv did not fail mechanically in this case? or truly a restriction of a non-condensible or other foreign object? Dan foss had a great article where they were getting an abundance of returned txv&apos;s when truly the failure was a restriction or a failed sensing bulb, drier filter. Nothing with the txv; since all the txv does is one thing: the rate of flow of liquid refrigerant into the evaporator. What was the bottom line in this case?

    3

  • @batoloco007 · 6 months ago

    According to my ac technician I am having a &quot;restriction&quot; on my unit. He &quot;explained&quot; the problem and I could not understand, in simple English, what he was saying. I am a 84 years old senior and I am afraid of a &quot;scam&quot;. Thanks

  • @ronselectrical8177 · 6 years ago (edited)

    If the screen is clogged should you replace the txv or just screen. I have one that&apos;s causeing high SH but normal SC. No dryer installed so I&apos;m thinking that&apos;s what caused txv to stop working properly.

  • @NeighborBones · 6 years ago

    This was somewhat useful but in my realword. I &nbsp;have 4-6 service calls and taking that txv out of the coil or hunting down hot water may not be practice. &nbsp; I wonder if there are other ways to recognize a faulty txv. what are the reasons of contamination like air or moisture? poor vacuuation practice? any others?

  • @SHOWKATHALIMOHAMMED-p1w · 4 years ago

    Hi sir. , Can we use infrared temperature gun for measure liner temperature for calculate SH &amp;SUB COOL

  • @taylerellis378 · 1 year ago (edited)

    Im getting the exact same reading as in this video I replaced the txv with external equilization and filter dryer today and still the same issue. 🎉 love hvac work sometimes. High subcoolling 12, high superheat 32, fan is good and moving lots of air, both coils are clean, what gives. Defective new txv? Do I replace it again. Idk Ug. I did a pump down and vacuum pumped to 200 microns and held so thats good, I did notice the oil that comes out of suction line is very foamy, did not take an acid test yet, noticed after the repair. R22 system with mineral oil. I also checked the temp of liquid line at cu and at indoor coil 1 degree difference so no restriction on the liquid line to txv. My liquid line is 76 degrees and oa temp is 77. So thats not good either. I did not see a fiter dryer inside the cu but im starting to think I need to go back and find out for sure maybe I missed it inside the cu coil and its restricted but not icing up. Idk youd think id have a temp difference on the liquid line at cu compared to liquid line temp at the evap if that was the case though. So im still spinning my wheels on this one.

  • @acservicetechchannel · 6 years ago

    -Do you have what it takes? Quizzes: <a href="https://www.acservicetech.com/quizzes">https://www.acservicetech.com/quizzes </a><br> -Our Articles with many descriptive pictures: <a href="https://www.acservicetech.com/articles">https://www.acservicetech.com/articles </a><br>-Facebook posts every other day! <a href="https://www.facebook.com/acservicetech">https://www.facebook.com/acservicetech</a>

    1

Up next

LIVE

How to Diagnose A Bad TXV

Ideal Conditions · 80K views

LIVE

EEV vs TXV Metering Device Operation, Efficiency, Additional Parts, & Evaporator Coil Function!

AC Service Tech LLC · 46K views

LIVE

Avoiding TXV Confusion & Misdiagnosis

Jersey Mike HVAC · 22K views

LIVE

Troubleshooting Indicators for a Liquid Line Restriction, Low Airflow, Low Charge! Check the Charge!

AC Service Tech LLC · 294K views

LIVE

Should You Replace a Bad TXV with a Piston? & TXV Diagnosis!

AC Service Tech LLC · 130K views

LIVE

Frozen Evap Coil Troubleshooting: Liquid Line Restriction, Low Airflow, Low Charge!

AC Service Tech LLC · 160K views

LIVE

Static Pressure: What It Is, Why It Matters, and How to Read It

Jersey Mike HVAC · 86K views

LIVE

40 VACUUM PROCEDURE TIPS for HVAC Techs! Avoid Frustration and Save Time!

AC Service Tech LLC · 233K views

LIVE

How to Test a TXV | HVAC Troubleshooting for Beginners

Pioneer HVAC Controls · 65K views

LIVE

Charging an R-410A AC Unit that is Very Low on Refrigerant with the Subcooling Method!

AC Service Tech LLC · 253K views

LIVE

Why and How to Adjust a TXV / TEV

HVAC School · 516K views

LIVE

Goodman Air Conditioner Repair - Liquid Line Restriction

The DIY HVAC Guy · 15K views

LIVE

HVAC 106 Scenario Restriction and non-condensable

Love2HVAC with Ty Branaman · 50K views

LIVE

How to Read SUPERHEAT and SUBCOOLING

Word of Advice TV · 839K views

LIVE

Trump Pressures Nvidia to Reinstate CEO Jensen Huang & He Tries to Explain Calling Putin His Friend

Jimmy Kimmel Live · 4.4M views

LIVE

MASTER the Thermostatic Expansion Valve in the HVAC Industry!

Taddy Digest · 113K views

LIVE

TXV Diagnosis: Superheat, Subcool & Split Temps

HVAC School · 48K views

LIVE

HVAC Metering Device Types: EEV, TXV, TEV, Piston, Capillary Tubing! Function, Location, Problems!

AC Service Tech LLC · 131K views

LIVE

The Refrigeration Cycle Put Plainly for Diagnostics

Jersey Mike HVAC · 108K views

LIVE

The Refrigeration Cycle Controls, Changing Conditions & Diagnostics

Jersey Mike HVAC · 28K views

YouTube, with the door locked.

Aegis plays a clean stream instead of YouTube's player, so pre-roll ads, trackers, and fingerprinting never ride along. Drop Shields any time if you want the official player back.