Ads skipped

The Mysteries of AM2 and AM2S - End Point Assessment

121K views · Mar 29, 2023 · Science & Technology

Comments · 107

  • @efixx · 3 years ago · pinned

    🚨Free learning🚨<br><br>Exciting news… the eFIXX training central has been launched with free electrical training and certification 👇🏻 sign up with the link below. <br><br><a href="https://training.efixx.co.uk/#/home">https://training.efixx.co.uk/#/home</a>

    5

  • @ainsleiparker9068 · 3 years ago

    Just a few tips for anyone sitting their AM2s close to the post date of this video. The metal conduit is a 90 from an enclosure to a through box, then a double set from the through box to another enclosure, so over egg your measurements, and pay attention to the tolerances. The maximum demand for the installation was pre filled out for my exam. The pvc conduit requires a &apos;bubble&apos; over a preset piece of conduit to a 90 (20-25mm), and you can use a coupler, so my advice would be do the bubble and use the coupler, it&apos;s in the spec! You are allowed to ask for more conduit if you mess it up, to a maximum of 3 times, then you will be given a pre bent piece! However this may impact your result. Pay attention to the DOL (random conductor not connected on the start circuit) and make certain the phase rotation is correct. When doing the inspection a testing, you are allowed to put right any mistakes made during the install phase. The key from the lock out kit has a hook in your bay that it belongs on, NET have deemed that a &apos;safe&apos; place. Be acquainted with using a £20 multimeter as NET deems this a better tool for fault finding rather then £600 worth of Megger/Kewtech/Metrel. And as always, read the spec!

    69

  • @britannic2000 · 3 years ago

    One thing I do when installing accessories, sockets switches etc which I think would be good to teach at college, a socket for example, wire up then push socket into back box pull back out and re tighten terminals, the conductors in terminals move as they are pushed into the back box the amount of accessories I have opened up and the conductors have fallen out, I wished I had re trained in plastering, all you need is a hawk, trowel and a criminal record, the hassle in this industry now as a trade the rewards don’t match.

    13

  • @johndillon5290 · 2 years ago

    Did my AM2 in the late 80s in Enfield when it first came out. Failed first time on the testing because I had never done testing before, this was back in the days of wind up Meggers. I actually walked off the test as soon as the instructor wheeled out a trolley of multiple testers in front of me. I thought &apos;I&apos;m wasting my time here&apos; My boss wasn&apos;t too happy. I did a pre course before the next attempt and sailed through it.

    4

  • @stevespoor6567 · 3 years ago

    Finished mine today….. now the 5 day wait

    13

  • @kingofgame.official · 3 years ago

    I did mine at AM2 Woodford Green. Assessor was great and made me feel so comfortable. It is a few long days so be prepared. I highly recommend to go to this centre if its close by.

    11

  • @eddie_pegasus_electrical · 2 years ago

    A great guidance for learners for their AM2 / AM2S. <br>A must watch if you are going through this process.<br>Well done guys <br>👊😎👍💙

    2

  • @MeganWhinnett-Slade-v1p · 8 months ago

    Is there an updated one for the new AM2 for 2026 please? :)

    2

  • @steve97384 · 2 years ago

    In your safe isolation video, you had the lock etc ready on the top of the board enclosure, I was always to not to put anything on top at college. Great video BTW.

  • @sergiofernandez3725 · 3 years ago

    Good video guys. &nbsp;I am sure this will help a lot of people preparing for their AM2/S/E

    4

  • @Gta6-Clips-New-2027 · 3 years ago

    I did my am2 just before they allowed personal tools which was annoying because I struggled a lot with the knackered side cutters they gave me, mostly because i use rounded cutters rather than side cutters in real life 🤦‍♂️

    12

  • @IwokeUpInSOMA · 2 years ago

    <a href="https://www.youtube.com/watch?v=UeqLC62ugY8&amp;t=1372">22:52</a> would be interesting for you guys to make a video on (or some yt commenters to leave some examples of) more of these types of things.<br><br>I.e. calling twin &amp; cpc &quot;twin and earth&quot; etc.<br><br>Would be keen to know what other correct vs incorrect, or just outdated terms like this exist!

Up next

LIVE

The AM2 Hack: How to Ace Your Assessment ✅

Scolmore Group · 13K views

LIVE

Fault Finding: 2-way Lighting Scenario

LEDA Academy · 2K views

LIVE

Essential tools for apprentice electricians

eFIXX · 12K views

LIVE

How to put a 90 Degree Bend and a Double Set into one length of Steel Conduit!

eFIXX · 132K views

LIVE

Webinar: Lighting control with KNX and DALI

KNX USA · 18K views

LIVE

AM2S - Section B: Dead Tests: Insulation Resistance

LEDA Academy · 6.9K views

LIVE

AM2 and AM2S Hints and Tips for the Electrical Apprenticeship end Point Assessment.

GSH Electrical · 43K views

LIVE

Steel Conduit Bend, Set and Measure AM2s

Heads Up 4 Sparkies · 188K views

LIVE

Insulation Resistance AM2

Sparky By Fifty · 24K views

LIVE

Section C - Inspection, testing and certification of the composite installation from the AM2

Pure Electrical Training - by Adrian Davey · 63K views

LIVE

TYPE A RCDs ❌ Why does my multi-function tester show a FAIL?

eFIXX · 41K views

LIVE

Where Does Electricity Actually Go When It's Earthed? — Britain's Earth Wire Explained

Behind the Ordinary · 27K views

LIVE

Safe isolation procedures #am2 #electrician #electricalapprentice #electricaltraining #kewtech

Electrical Courses Ltd · 23K views

LIVE

🔥 RING CIRCUIT FAULT FINDING – AM2 TIP! ⚡️

Elex-electrical · 10K views

LIVE

AM2S - Section A2-A6: Part 2: Steel Conduit Part 1

LEDA Academy · 7.2K views

LIVE

16 Common Things Older Car Owners Don’t Know Are ILLEGAL in the UK in 2026

Gary Whitlock · 164K views

LIVE

Did The Regs Ban These Junction Boxes?

eFIXX · 307K views

LIVE

Section E - Fault diagnosis and rectification - AM2 pre assessment manual

Pure Electrical Training - by Adrian Davey · 72K views

LIVE

AM2 Assessments - DO's and DONT's ✍️

Scolmore Group · 20K views

LIVE

AM2 and/or AM2S - Central Heating / Sustainable Energy Control Circuit

XS Training Ltd · 108K views

YouTube, with the door locked.

Aegis plays a clean stream instead of YouTube's player, so pre-roll ads, trackers, and fingerprinting never ride along. Drop Shields any time if you want the official player back.