Testing an Extraneous Conductive Part (High or Low)
12K views · Jun 1, 2022 · Education
Comments · 28
@danielteyehuago7 · 2 years ago
Wow! This is video very informative and the best tutorial on the topic for me so far. I really appreciate it. Thanks for sharing it with us.
2
@freezefoot · 4 years ago
Good to see you back.Thanks for the video.Look forward to live demos.
@HeatSoaked · 3 years ago
Is there a meaningful risk in an equipotential zone with diverted neutral currents due to a broken pen conductor. Both upstream or downstream? How best to avoid the currents circulating around pipe work and the incoming supply?
1
@fairisfairfairisfair9788 · 4 years ago
Nice to see you are making videos again. You are the best ... please help me prepare for my inspection and testing exams with some videos...thanks. And again...you are the best
@ramzg5402 · 4 years ago
Hi Sir, I really appreciate your videos, they are amazing.
@THECARKUS · 3 years ago
Thank you. Really useful content.
@zjzozn · 1 year ago (edited)
Thank you… really clear visuals and explanation…. You don’t learn this on your regulations course or i’ve forgotten. 👍🤠
@Tryingtimes007 · 4 years ago
Great description & animation 👍
@LTB547 · 3 years ago
Hi, great video,<br>Could you please explain what the Ib would be in that equatian when the installation being tested is of an older edition and protected by a bs3036 rewirable fuse as it's protective device.<br>Thanks
@DontTestJJ · 1 year ago
Thanks for your video ! <br>I have a question:- <br>I have a plastic main incoming pipe which then goes to copper around the immersion and then back to plastic until the start of an air source heat pump (which is outside)<br><br>Now I get connected onto the MET 0.22ohms on these pipes by the immersion- is this not picking up the Earth through the immersion based on this ? <br><br>My logic then was to remove the main Earth and clamp onto this and then touch the pipe with the meter -the reading is greater than 999k ohms. <br>My question here is does this need to be bonded or not ?
@ja_adam_ · 3 years ago
Hi, do you know much about shaver sockets / isolating transformers? I’m just trying to understand at college we've been told that voltage flows when there's a different potential as you say. But how do you not get a shock touching a live part from a shaver socket if you're other hand is touching a tap. But you would get a shock if you touch a live in a switch while you're stood on ground or touching a tap?
@lifter98 · 1 year ago
So, with 211v on the kettle…<br>Wouldn’t some voltage appear on the pipe - the difference between the Volta on the kettle and the voltage on the pipe being the touch voltage…?
Up next

What is the voltage at the fault?
JPElectric · 3K views

Supplementary Protective Bonding and Touch Voltage
JPElectric · 10K views

Testing Zs - Why it is so important?
JPElectric · 28K views

Earthing & Bonding - Part 3 : Supplementary Protective Equipotential Bonding
John Ward (jwflame) · 108K views

SCHEDULE OF TEST RESULTS. Electrical. How to complete correctly.
LEARN ELECTRICS · 34K views

I finally saw quantum physics with my own eyes... (It's spookier than I expected)
Veritasium · 21M views

Maximum Earth fault loop impedance
JPElectric · 22K views

Understanding your test results - Vital knowledge when testing.
JPElectric · 4.4K views

2391 - RING CIRCUIT TESTING – RESISTANCE – R1+R2
LEARN ELECTRICS · 32K views

Continuity Testing for Electrical Installations
John Ward (jwflame) · 356K views

Grounding and bonding: Definitions and details
Eaton · 143K views

To Bond Or Not To Bond 🤔 | Extraneous Conductive Parts
Faultless Electrical Services · 7.3K views

Earth Fault Loop Impedance Test & Prospective Fault Current Test
Trade Skills 4U · 755K views

Insulation Resistance Part 2 - The problem with the neutral conductors
JPElectric · 12K views

OBSERVATION CODES FOR EICR - ELECTRICAL INSPECTION AND TEST - THE RIGHT CODE AT THE RIGHT TIME
LEARN ELECTRICS · 19K views

FINDING A SHORT PART ONE – ELECTRICAL SHORT CIRCUITS AND EASY WAYS TO FIND THEM – FAULT FINDING TIPS
LEARN ELECTRICS · 31K views

5 Formulas Electricians Should Have Memorized!
Electrician U · 1.5M views

TESTING ZE – TNCS – TNS - TT - WHAT ARE THE DIFFERENCES BETWEEN THE EARTHING SYSTEMS
LEARN ELECTRICS · 43K views

2391 INSPECTION & TEST QUESTIONS AND ANSWERS FOR EXAMS AND ASSESSMENTS – WITH FULLY WORKED ANSWERS
LEARN ELECTRICS · 50K views

How to do an EICR start to finish - Electrical Safety Inspection and Test
Mark The Sparky Allison · 108K views