Should We Get a Heat Pump? Everything You Need To Know About Air-to-Water Heat Pumps
60K views · Sep 10, 2026 · Science & Technology
Comments · 247
@MrEV · 2 months ago · pinned
Do you have an air-to-water heat pump? How are you finding it? And do you think we should go A2A or A2W?<br><br>If you'd like to get a heat pump, I've teamed-up Heatable to get you a discount of £150 if you use the code MISTEREV150 or the following link when you get a quote: <a href="https://misterev.co.uk/heatpump">https://misterev.co.uk/heatpump</a><br>(or the same discount for air-to-air if you'd prefer: <a href="https://misterev.co.uk/aircon">https://misterev.co.uk/aircon</a> )
9
@NZherewecome · 2 months ago
Air to water for that two story building. Your single story is perfect for air to air. <br>Your ducted system would be out the way in the loft, with a percentage of fresh air on its return also. <br><br>With the absolute bonus of cooling in summer.
6
@IanReid-n6d · 2 months ago
A2A multi-split for you Andrew... having a blank slate and a bungalow with access to loft for distribution is great. Cooling is going to become more and more relevant...
6
@JohnThomas-ey1hx · 2 months ago
Good honest overview. In your bungalow starting with a blank slate I would go A2A, but instead go for a central distribution unit in the loft and then ducted off into ceiling vents in each room which looks far better than separate wall mounted units and least disruptive. My brother-in-law has just had this system fitted in his bungalow using Daikin system and working really well as he has individual heating/cooling control in every room. Decisions, decisions! Good luck making your final choice.
6
@gavinmiskelly · 2 months ago
We just installed A2A during the summer, really good timing given the summer we had. I cant convince my wife to get rid of the gas central heating, and we have a multi-fuel fireplace which we apparently need for the 'ambiance'. I quite like having the redundancy of the 3 options for the winter, and given I couldn’t get a grant for not getting rid of a gas boiler, A2A was the cheapest option for me (£4.5k for a 3 way split system)
5
@MentalLentil-ev9jr · 2 months ago (edited)
Whether you go air-to-water or air-to-air, they are both great from an environmental perspective. It's really just about choosing the better solution for your individual needs based on the advantages and disadvantages of each.<br><br>For me, the comfort of the air-to-water system wins out; I love it. However, based on last summer and future hot summers that will get worse, I may get a small mini-split to provide cooling to some of the rooms.
3
@petergedge9629 · 4 weeks ago
Great to see a normal house, and a normal install. Too many videos focus on big houses with complex systems, which are great to see, but 99% of us are just looking for normal installation in a normal family house.<br><br>Cheers.<br><br><br>.......expected Richard to have a bigger battery system!
1
@colingoode3702 · 2 months ago
With no existing Rads or pipework infrastructure in your bungalow Andrew, I would say an A2A system is your best bet. A single ducted unit in the loft with, if required, zone dampers for individual room temperature control. Or, multiple loft mounted ducted units to serve individual rooms. Ducted units are more expensive (kit & labour to install) but are more discrete than an in room wall mounted unit which are much quicker & cheaper to install. As you know you also get the benefit of summer cooling with an air to air system. Our A2A system came in very handy during the recent summer heat waves & allowed us to get a good nights sleep without having to open any upstairs windows & let any bugs or noise in. <br>New multi A2A systems from some manufacturers can now incorporate HW heating as well. If not then the other options are a simple electric immersion heater / tank (which you probably already have), Mixergy iHP Heat pump tank or, a SunAmp Thermino phase change thermal store which can be charged up overnight on cheap electric or during the day on excess solar. <br>If you had existing rads & pipework installed it might be a different story but Air 2 Air would seem to be the most logical (& probably cheaper) solution for you. <br>I still have a gas boiler & rads but I'm gradually changing to A2A systems. 3 out of 4 bedrooms & our conservatory have wall mounted A2A units now. 30ft lounge, kitchen & one remaining bedroom to go + the hot water to sort out. I'm also changing my existing solar inverter & batteries at some point for a larger system. The existing 3.6kWh inverter is just not big enough.
2
@EverydayLife621 · 2 months ago
... do it once and do it right, save up, move out for a month, get in underfloor wet heating installed via heakgeek (I got converted watching John Morgan 's home get repaired via skillbuilder )
4
@youroddsox · 2 months ago
Best to just think of the house like one huge battery. Just trying to keep it topped up with heat otherwise spending a lot of energy charging and discharging it.
9
@pmbpmb5416 · 2 months ago
Use K3 radiators , they are a bit wider but do not intrude as you would expect .<br>Add as much insulation as you can . The more you can lower the flow temp the cheaper it is to run , as long as you are remaining at the property the more it obviously repays your investment .
2
@roderickmain9697 · 2 months ago
Agree with nearly all of what Richard says. The micro-bore pipes are an issue for flow (so Im told). What we couldnt tell was that one of our radiators had it under the floor but for some reasom swapped back to "standard" bore to go through the floor. I am rather annoyed that when we had a new (quite large) rad put in for the kitchen/Diner they didnt replumb it. It does still get warm but its a lot slower to react compared to the others.<br>Our house had an oil fired boiler with radiators throughout. Three radiators (including the one above) needed updating to larger varieties. We had to get a new towel rail as the old one sprang a leak (seemed to be age related) and its a bit larger (and a bit warmer) than the old one. Conservatory wasnt heated and we've put in bifold doors with double glazing so we can isolate it in winter Heat losses in the conservatory are ludicrous so its better keeping out of it when its sub-zero outside. <br>Our first year here (5 years ago) our oil boiler cost us just over £3000 for oil alone. Our second year cost less than £2500 for all the electricty - including EV charging, running the heat pump, cooking, everything. <br>As Richard says, our heatpump is "on" all the time. Ours is set to 22c (and 20c at night) as the thermostat is in the utility room and its not representative of the house. The house runs at about 21/19 as Richards does., If The utility room is above 22 the heatpump doesnt run - apart from heating the water tank. Only thing I would say is that make sure the timing goes back to 22c a couple of hours before you want to get up.<br><br>Oh...some people will say "you cant run heatpumps if its too cold outside". (How cold is too cold?) We've experienced temperature as low as -16c outside and its still been warm inside. I dont think there is one year so far where it hasnt reached -10 overnight aome point.<br><br>For your place, Andrew, because you are starting from scratch, Id say its hard to call which way is best to go. My feeling is that A2W is more efficient and the hot water tank doesnt need a separate system. In the summer, our place's south facing rooms and conservatory have got quite warm but we can open a few windows and let it out. If A2A gives you an aircon ability that might be worth having if the outside is up in the high 30s outside..
4
Up next

We Spent £4,000 Heating a Bungalow… So We Got a Heat Pump
Andrew Till / Mr. EV · 144K views

Air to Air vs Air to Water Heat Pumps: Choose Wisely!
Gary Does Solar ☀️ and Heatable · 75K views

Out With The Old, In With The New! Robert's Heat Pump Install!
Everything Electric TECH · 122K views

Best of Both Worlds? Heating and Cooling with an Air-to-Air Heat Pump
Andrew Till / Mr. EV and Tim & Kat's Green Walk · 133K views

Switching from Oil to a Heat Pump: Costs & Savings
dwellow · 1.5K views

Heat Pump Coming! Big News, Very Sad News, a Grumpy Wife, and Coffee (Obviously)
Andrew Till / Mr. EV · 84K views

I Wish I’d Known This Before Installing Solar
Andrew Till / Mr. EV · 266K views

Air-to-Air vs Air-to-Water Heat Pumps: Which Is Best for UK Homes?
Renewable Heating Hub · 9.1K views

I Tried Getting a Heat Pump - Here’s What Happened…
Gary Does Solar ☀️ · 74K views

Heat Pumps Explained — And Tested | Guy Martin
Guy Martin · 1M views

What’s Worrying Heat Pump Owners? Graham Hendra Explains
Renewable Heating Hub · 12K views

Octopus Heat Pump Survey HAS Hidden COST!
Nicolas Raimo · 96K views

I Spent 90 Days with a Octopus Heat Pump and was SHOCKED by the Costs!
Jonathan Tracey · 353K views

How Did Our Heat Pump Go So Wrong? The Truth Revealed
Renewable Heating Hub · 14K views

EcoFlow STREAM AC 5000: 5kWh Plug-in Battery vs Installed Home Battery
Andrew Till / Mr. EV · 56K views

I Spent 6 Months with an Octopus Energy Heat Pump and was blown away by the running costs!
Jonathan Tracey · 19K views

I Was Forced To Buy A Heat Pump
Heatable · 36K views

Heat Pump at –3°C: The Truth No One Tells You
UpsideDownFork · 144K views

Could This Battery Boiler Replace Gas AND Heat Pumps?
Everything Electric TECH · 231K views

Can Guy Martin Beat Energy Bills for Good? | House Without Bills
Guy Martin · 448K views