How amazing AC-coupling works in Deye/Sunsynk inverter - limiter works using frequency, perfecto!
23K views · Jun 7, 2024 · Science & Technology
Comments · 175
@ТоликШипер · 1 day ago
Мене цікавить як можна підключити до трьохфазного гібридного інвертора дея через ген порт звичайний однофазний інвертор - до якого вже підключити генератор
@V4per · 3 months ago (edited)
Good day sir,<br><br>(maybe I missed this in one of your videos....)<br><br>I have Huawei SUN2000 10kW AC coupled to gen port of Deye 12kW.<br>The Huawei SUN2000 10kW has Luna batteries, and in special cases actually take power from the Deye through gen port to charge them. That's how I know that deye gen port is bi-directional even in Micro Inverter mode.<br><br>Does this however mean that I can connect a load in parallel with the SUN2000 on the Deye gen port (when configured to Micro inverter mode)? (I actually cannot find such an implementation on the internet).<br><br>I want to place an EV charger in parallel with the SUN2000 10kW on the gen port of Deye.<br><br>So EV charger will be supplied by both SUN2000 inverter and Deye inverter if required. This is to ensure the SUN2000 mostly carries the EV charging load, so that Deye is mostly available for other home loads.
@BenFlood-bx8vu · 6 months ago
Is your string inverter connected via the Load Port or AUX/GEN? I want to buy my string inverter on AUX/Gen and am curious if frequency shifting will still work
@petpvb · 6 months ago
Can the deye 10kw inverter actually handle the full power of the 20k huawei inverter. As it is rated for only about 15amps of balanced load. And the huawei can put out close to 27amps balanced. Or does the deye regard this like a pass through power the same way it can pass though 45amps per phase of power from the grid?
@krzysztofszela3998 · 11 months ago
Jaką masz wersję firmware, bo bardzo ładnie Ci to pracuje. U mnie bardzo ogranicza moc na porcie gen przez podwyższenie częstotliwości
@markhandy9353 · 11 months ago
Please where did you order your unit from?
@mariusfauru · 11 months ago
Does Sdm630 Modbus v3 work with Deye???
@mariusfauru · 11 months ago
If i have a one fase microinverter pv system, how do i make the connection on the Gen 3 phase connection? I only use the Neutral and one fase?
@Drdestani · 1 year ago (edited)
Thank you for this video,<br>"Thank you for this video. I would like to ask if it's possible to connect a 5KW single-phase inverter to the 12KW three-phase DEYE inverter as a microinverter input. I mean the monophase inverter to 3Phase DEYE inverter via the Gen port, to use it as a power supply for the main system the DEYE 12 KW inverter."
@lioneladams6216 · 1 year ago
Good afternoon, I have the Deye 10kw inverter with batteries and solar panels connected to it. Zero export to CT activated with no Solar sell. I have Smartload active and would like to know if I should change it to Micro inv input instead? Best Regards.
@mecenasonoffgrid · 1 year ago
Can you tel me. What settings you change in ongrid inwerter !? ???
1
@alincioaba464 · 1 year ago
Just giving you a big like just for making russions idiots for attacking ucraina.
3
Up next

The Hidden Problem With Home Batteries
Undecided with Matt Ferrell · 1.3M views

Solar Panels & How They're Installed | Basic to Basics | Episode 2
MC Electrical · 4.5K views

Messed up BIGTIME - Sigenergy 10kW - Bifacial Panels....
Mark The Sparky Allison · 35K views

EEVblog 1620 - Deye Solar Hybrid Inverter EXTREME TEARDOWN
EEVblog · 140K views

Vorführung der Stromaggregate Funktion beim deye hybrid inverter! Es sind leider einige Bugs vorhand
Mr.mining · 41K views

I Wish I’d Known This Before Installing Solar
Andrew Till / Mr. EV · 205K views

I Finally Upgraded to a Deye Inverter – You Won’t Believe the Difference!
ErCan Everything · 279K views

Setting-Up and Commissioning a DEYE inverter - Step-by-Step Tutorial
SOLARKIT Europe · 219K views

Deye hybrid inverter, AC coupling at the grid input: PV surplus in your hands!
Roland W · 22K views

Basic Sunsynk Training course 25 March 21
Sunsynk · 62K views

Deye inverter setup in microgrid/ac coupling with ongrid inverter for adding storage 2025
Full Electric · 22K views

Cum functioneaza DEYE Hibrid in Microgrid/AC Coupling cu invertor Ongrid ?
SolarTech · 42K views

How to AC Couple the Sunsynk All-In-One Inverter with Keith & Joe
Sunsynk · 17K views

Deye Hybrid-Inverter, how to AC-Couple on Grid Input: Total control of Excess Energy from your PV
Roland W · 23K views

DEYE + SMART LOAD + GEN
Rafał Fatyga · 5.7K views

🚨 PLÖTZLICH ESKALIERT DIE RUNDE! Lisa Eckhart sagt EINEN SATZ – PUBLIKUM RASTET KOMPLETT AUS!
Scharfer Blick · 52K views

Sunsynk Inverter Training (Basic)
Tripple Hydro and Energy · 72K views

AC Coupling Explained
NAZ Solar Electric · 16K views

Using the auxiliary load on the SunSynk-inverter #hybrid inverter #solar inverter#signature solar
Sunsynk · 35K views

Solar Panel Shading (Part 1): Are Optimisers and Micro inverters Worth It?
Gary Does Solar ☀️ · 239K views

Sigenergy hybrid battery, installation and review by a solar professional! Whats it really like?
Joondalup Electrical Services · 42K views

Discussion and battery settings for Deye inverter (CAN communication and manual voltage setting)
Full Electric · 62K views

12kW Solar System Explained Step-by-Step ⚡ MPPT, PV Strings, Wiring & Safety Guide
Ak Electric DIY · 276K views

Deye AC Couple (Load, Grid, GEN) 🔋⚡ How to expand Deye with additional inverters?
Lewa Ręka · 20K views

American Mind Blown by European Bus Driver Skill & Maneuvers
IWrocker · 46K views

2 Years With Solar & Batteries — Was It Worth £13,491?
Considered · 146K views